The rotator interval was defined as a triangular structure, where the base of the triangle was the coracoid base, the upper border was the anterior margin of the supraspinatus, and the lower border was the superior margin of the subscapularis muscle-tendon unit. We evaluated the rotator interval dimensions in 15 shoulders from 10 lightly embalmed adult cadavers in 3 shoulder arthroscopy positions: 0 degrees of abduction and 30 degrees of flexion (beach chair [BC]), 45 degrees of abduction and 30 degrees of flexion (lateral decubitus 1), and 70 degrees of abduction and 30 degrees of flexion (lateral decubitus 2). In each shoulder position, measurements were made in neutral rotation (NR), 45 degrees of external rotation (ER), and 45 degrees of internal rotation (IR). The coracoid base lengthened with IR in all positions and shortened in ER in the lateral decubitus position but not in the BC position. Abduction significantly lengthened the coracoid base, which was shortest in the BC position with ER (24 +/- 4 mm) and longest in the lateral decubitus 2 position with IR (33 +/- 5 mm). The coracoid base, where sutures are placed during plication of the interval, was observed to lengthen and, therefore, loosen with IR and abduction. To prevent postoperative ER restriction, plication should be made in ER or neutral rotation when operating in the BC position and the degree of abduction should be decreased and the shoulder held in ER when operating in the lateral decubitus position.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jse.2007.11.007DOI Listing

Publication Analysis

Top Keywords

lateral decubitus
20
coracoid base
16
rotator interval
12
degrees abduction
12
abduction degrees
12
degrees flexion
12
decubitus position
12
interval dimensions
8
shoulder arthroscopy
8
arthroscopy positions
8

Similar Publications

In abdominal X-ray examinations, radiosensitive organs such as the gonads within or near the imaging region are at risk of radiation exposure. Minimizing the dose to these organs is crucial to reducing unnecessary radiation. This study utilized optically stimulated luminescence dosimeters (OSLDs) to measure the radiation dose to the male gonads at varying kilovoltage peak (kVp) settings while keeping the milliampere-seconds (mAs) constant across different radiographic projections.

View Article and Find Full Text PDF

Airway management in the prone position presents significant challenges and carries the risk of encountering a difficult airway situation. Here, we present two adults who sustained traumatic knife injuries to the back and required surgical intervention. Due to the potential life-threatening complications associated with dislodging the knife, traditional supine and lateral decubitus positions were not feasible for airway management.

View Article and Find Full Text PDF

Prone Transpsoas Lumbar Interbody Fusion for Degenerative Disc Disease.

JBJS Essent Surg Tech

January 2025

Department of Neurosurgery, Center for Neuroscience and Spine, Virginia Mason Medical Center, Seattle, Washington.

Background: Prone transpsoas lumbar interbody fusion (PTP) is a newer technique to treat various spinal disc pathologies. PTP is a variation of lateral lumbar interbody fusion (LLIF) that is performed with the patient prone rather than in the lateral decubitus position. This approach offers similar benefits of lateral spinal surgery, which include less blood loss, shorter hospital stay, and quicker recovery compared with traditional open spine surgery.

View Article and Find Full Text PDF

Introduction We aimed to assess whether partial hepatectomy has an influence on conventional and speckle tracking parameters on echocardiography in living liver donors in the early postoperative period. Methods This study was a retrospective study to investigate the cardiac effects of liver donation after the transplant operation in a high-volume liver transplant center. Ninety living liver donors were included in the study.

View Article and Find Full Text PDF

Background: Diabetic patients may have neuropathy-induced gastroparesis predisposing them to aspiration. Point-of-care gastric ultrasonography (GUSG) is useful in the qualitative assessment of the antrum and quantitative prediction of gastric volume (GV) in diabetic patients. In this study, we compared the GUSG findings between fasting diabetic and non-diabetic patients in the elective preoperative setting.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!