A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Pulse repetition time and contrast enhancement: simulation study of Gd-BOPTA and conventional contrast agent at different field strengths. | LitMetric

Objectives: To investigate theoretically enhancement and optimal pulse repetition times for Gd-BOPTA and Gd-DTPA enhanced brain imaging at 0.23, 1.5, and 3.0 T.

Methods: The theoretical relaxation times of unenhanced, conventional contrast agent (Gd-DTPA) and new generation contrast agent (Gd-BOPTA) enhanced glioma were calculated. Then, simulation of the signals and contrasts as a function of concentration and pulse repetition time (TR) in spin echo sequence was done at 0.23, 1.5, and 3.0 T. The effect of echo time (TE) on tumor-white matter contrast was also clarified. Three patient cases were imaged at 0.23 T as a test of principle.

Results: Gd-BOPTA may give substantially better glioma-to-white matter contrast than Gd-DTPA but is more sensitive to the length of TR. These characteristics are accentuated at 0.23 T. Optimal TR lengths are shorter for Gd-BOPTA than for Gd-DTPA enhanced imaging at all field strengths. TR optimized for Gd-DTPA may thus give suboptimal contrast in Gd-BOPTA enhanced imaging. Higher enhancement with Gd-BOPTA is further accentuated by short TE.

Conclusion: Appropriate TRs at 0.23 T appear to be approximately 300 to 400 milliseconds and 250 to 300 milliseconds, at 1.5 T 500 to 600 milliseconds and 400 to 450 milliseconds and at 3.0 T 550 to 650 milliseconds and 475 to 525 milliseconds using Gd-DTPA and Gd-BOPTA, respectively. For Gd-BOPTA enhanced imaging, it seems justified to optimize TR according to contrast and seek options like parallel excitation (Hadamard encoding) for increasing the number of slices and SNR.

Download full-text PDF

Source
http://dx.doi.org/10.1097/RLI.0b013e3181636eb8DOI Listing

Publication Analysis

Top Keywords

pulse repetition
12
contrast agent
12
gd-bopta enhanced
12
enhanced imaging
12
gd-bopta
9
repetition time
8
contrast
8
conventional contrast
8
field strengths
8
gd-bopta gd-dtpa
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!