A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A sensitive and quantitative assay for normal PrP in plasma. | LitMetric

Transmissible spongiform encephalopathies can be transmitted by blood transfusion. The risk of spreading the disease among the human population could be mitigated with the implementation of a blood screening assay. We developed a two-antibody assay for PrP detection in plasma using the ORIGEN technology with a protocol modification to improve the limit of detection and to increase the sample volume assayed. In the standard 200 microL format, the assay had a detection limit of 7-10 pg of recombinant PrP and 3 pg in 1 mL final volume implementation. PrP concentration measured in normal and scrapie-infected hamster brains was 7.5+/-0.9 and 57.3+/-9.6 microg/g, respectively. After a concentration step with an immuno-affinity resin, plasma PrP(c) was detected by Western blot and its concentration was measured at 3.5+/-0.8 ng/mL. From these data and assuming that blood has the same specific infectivity as brain, we estimated the concentration of abnormal PrP in hamster-infected plasma to be 32 f g/mL. The assay also detected abnormal brain PrP spiked into plasma although the limit of detection was affected. This is a novel and sensitive assay for the detection of PrP in plasma that could be developed into a platform for a plasma-based TSE test.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jviromet.2008.01.028DOI Listing

Publication Analysis

Top Keywords

prp plasma
8
limit detection
8
assay detection
8
concentration measured
8
prp
7
assay
6
plasma
6
detection
5
sensitive quantitative
4
quantitative assay
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!