Effect of sport-tinted contact lenses for contrast enhancement on retinal straylight measurements.

Ophthalmic Physiol Opt

Optics Department, Universidad de Valencia, Dr Moliner 50, 46100 Burjassot, Spain.

Published: March 2008

Purpose: To investigate the effect of two tinted contact lenses (CL) designed for outdoor sports activity on the psychometric determination of retinal straylight using the compensation comparison method.

Methods: Thirteen emmetropic subjects were randomly fitted with two different tinted Nike Maxsight (Bausch & Lomb, Rochester, NY, USA) CL in one eye, while the contralateral eye was fitted with a clear lens made of the same material (Optima 38, Bausch & Lomb). Three valid straylight measurements were taken on each eye before and a few minutes after lens insertion, when lens stabilization had occurred.

Results: The subjects' mean straylight values were 0.90 +/- 0.09 at baseline and 0.95 +/- 0.10 with the clear Optima 38 CL. Straylight values were 0.97 +/- 0.10 and 1.0 +/- 0.10 log units with the amber and grey-green tinted CL, respectively. Differences in straylight between baseline (without CL) and with the clear CL in place were neither statistically significant (p = 0.066) nor was there a significant difference between baseline and the amber CL (p = 0.052). However, the grey-green CL showed a statistically significant difference from baseline (p = 0.006). Differences in straylight with the clear CL compared with the grey-green CL were also statistically different from zero (p = 0.002) showing an increased straylight value for the tinted CL. These differences were variable, but consistent for each subject, thus those showing higher or lower changes with one tinted lens tended to show the same trend with the second lens (r(2) = 0.736).

Conclusions: Despite increases having been found in straylight values with tinted contact lenses, those changes are not likely to induce clinically significant changes in visual function under photopic conditions, even for the grey-green CL, which seems to increase straylight values more significantly than the amber CL. This difference between the tinted CL could suggest a wavelength dependence of straylight values, although this should be investigated further by controlling for pupil size and subjects' pigmentation, as well as by using neutral density filters.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1475-1313.2008.00541.xDOI Listing

Publication Analysis

Top Keywords

straylight values
20
contact lenses
12
+/- 010
12
straylight
11
retinal straylight
8
straylight measurements
8
tinted contact
8
bausch lomb
8
tinted differences
8
differences straylight
8

Similar Publications

Purpose: Propose new terminology and evaluate the effectiveness of Therapeutic Refractive Vitrectomy (TRV) for selective removal of vitreous floaters and opacities (VFO) utilizing Standardized Kinetic Anatomical Functional Testing of VFO (SK VFO Test) and new ultra widefield (UWF) OCT imaging techniques.

Methods: Retrospective analysis. Twenty eyes underwent TRV for symptomatic VFO.

View Article and Find Full Text PDF

Background: Homogeneous intraocular lens (IOL) calcification deteriorates patient's visual quality. There is a lack of functional and patient-reported data on patients with this material change undergoing IOL exchange surgery. The aim of this study was to evaluate subjective and objective outcomes following IOL exchange due to homogeneous IOL calcification to improve evidence-based patient counseling.

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to explore how calcium and phosphorus levels influence optical deterioration in intraocular lenses (IOLs) that have calcified.
  • Researchers analyzed 18 explanted IOLs, identifying differences between primary and secondary calcification by measuring straylight and light loss.
  • Findings revealed primary calcified IOLs had significantly higher calcium and phosphorus content, leading to greater optical impairment compared to secondary calcification, highlighting the importance of these minerals in visual quality deterioration.
View Article and Find Full Text PDF

Purpose: To identify the biometric factors associated with postoperative visual performance after uneventful phacoemulsification with multifocal intraocular lens (MIOL) implantation.

Methods: In this retrospective cohort study, 72 eyes of 72 patients implanted with the HumanOptics Diff-aAY MIOL were included. Preoperative examination data including the white-to-white distance (WTW), anterior chamber depth (ACD), axial length and corneal astigmatism were gathered through the electronic medical records.

View Article and Find Full Text PDF

The perception of halos and other night vision disturbances is a common complaint in clinical practice. Such visual disturbances must be assessed in order to fully characterize each patient's visual performance, which is particularly relevant when carrying out a range of daily tasks. Visual problems are usually assessed using achromatic stimuli, yet the stimuli encountered in daily life have very different chromaticities.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!