Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Vascular dysfunction in the coronary and peripheral circulations is an early prognostic marker of future cardiovascular events. Measurements of coronary and peripheral vascular function in resistance vessels can be made, but rely on invasive procedures, which make them unsuitable for routine application. An assessment of the direct correlation between vascular responses in skin and coronary vessels has not been made previously. In 27 normal healthy subjects (18-55 years of age), we examined the relationship between peripheral and coronary vascular function. Cutaneous perfusion was measured using the non-invasive technique of laser Doppler imaging during iontophoresis of acetylcholine and sodium nitroprusside, and cutaneous vascular conductance was calculated (laser Doppler perfusion/mean arterial pressure). Coronary flow reserve was measured using transthoracic echocardiography during intravenous adenosine infusion. Mean diastolic velocities were measured at baseline and peak hyperaemic conditions from the Doppler signal recordings. CVR (coronary velocity reserve) was defined as the ratio of hyperaemic to basal mean diastolic velocities. There were significant positive correlations between CVR and cutaneous vascular conductance for acetylcholine (r=0.399, P=0.039) and sodium nitroprusside (r=0.446, P=0.020). These results support the idea that peripheral measurements of skin blood flow are representative of generalized microvascular function including that of the coronary circulation in normal healthy subjects.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1042/CS20070431 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!