A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of an implantable infusion pump for sustained anti-HIV drug administration. | LitMetric

Factors such as insufficient drug potency, non-compliance and restricted tissue penetration contribute to incomplete suppression of Human Immunodeficiency Virus (HIV) and the difficulty to control this infection. Infusion via standard catheters can be a source of infection, which is potentially life threatening in these patients. We developed an implantable infusion pump, allowing to accommodate large volumes (16-50mL) of high viscous solutions (up to 23.96mPas at 39 degrees C) of anti-HIV agents and providing sustained release of medication: a standard Codman 3000 pump, which was initially developed to release aqueous solutions ( approximately 0.7mPas) into the spinal cord such as for pain medication, was transformed for release of viscous solutions up to 40mPas by adapting the diameter of the capillary flow restrictor, the capillary length and way of catheterisation--by placing the indwelling catheter in the vena cava. A pilot study of the pump implanted in 2 dogs showed continuous steady-state release of the protease inhibitor darunavir (25mg/dog/day administered for 25 days), thereby achieving plasma concentration levels of approximately 40ng/mL. Steady-state plasma levels were reproducible after monthly refill of the pumps. In conclusion, the implantable adapted Codman 3000 constant-flow infusion pump customized to anti-HIV therapy allows sustained release of anti-HIV medication and may represent an opportunity to reduce the pill burden and complexity of dosing schemes associated with common anti-HIV therapy.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijpharm.2008.01.029DOI Listing

Publication Analysis

Top Keywords

infusion pump
12
implantable infusion
8
viscous solutions
8
sustained release
8
codman 3000
8
anti-hiv therapy
8
pump
5
anti-hiv
5
release
5
development implantable
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!