A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Long-term bone tissue reaction to polyethylene oxide/polybutylene terephthalate copolymer (Polyactive) in metacarpophalangeal joint reconstruction. | LitMetric

The poly-L/D-lactide 96/4 joint scaffolds are used to engineer fibrous tissue joints in situ for the reconstruction of metacarpophalangeal joints. In this experimental study, a supplementary elastomeric stem made of Polyactive 1000PEO70PBT30 (a segmented block copolymer of polyethylene oxide and polybutylene terephtalate with 70/30 PEO/PBT ratio) was used to anchor the joint scaffold in the arthroplasty space. Eleven resected fifth metacarpophalangeal joints of minipig were reconstructed and evaluated radiologically and histologically for 3 years. Plain joint scaffold and Swanson silicone implant arthroplasties (11 of each) in metacarpophalangeal joints of minipig served as controls. Altogether fore limbs of eighteen minipigs were operated for the study. Deleterious tissue reaction with dramatic signs of osteolysis and inflammatory foreign-body reaction was observed around the Polyactive stems. The mean maximum diameter of the osteolytic stem cavity was statistically wider when compared to the mean maximum diameter of Swanson implant group during the first postoperative year. Numerous osteoclasts were found at the margins of the osteolytic areas. No direct bone contact could be seen. At 1 year osteoblastic regeneration and formation of new trabecular bone followed. Finally the foreign-body reaction settled, but the adjoining bones were at this stage highly sclerotic and composed of coarse trabeculae. In contrary to previous in vivo studies suggesting biocompatibility, osteoconductivity and capability to bond to bone, Polyactive 1000PEO70PBT30 stem in this setting caused massive osteolytic lesions and foreign-body reactions.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.biomaterials.2008.02.013DOI Listing

Publication Analysis

Top Keywords

metacarpophalangeal joints
12
tissue reaction
8
polyactive 1000peo70pbt30
8
joint scaffold
8
joints minipig
8
foreign-body reaction
8
maximum diameter
8
long-term bone
4
bone tissue
4
reaction
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!