In this study, the microtensile bond strengths of resin composites to dentin and enamel produced by recently introduced self-etching resins were determined. Included were two adhesives with self-etching primers, Clearfil SE (Kuraray) and Peak SE (Ultradent), four self-etching adhesives, Optibond All-In-One (Kerr), Clearfil S3 (Kuraray), Adper Prompt L-Pop (3M ESPE) and iBond (Heraeus Kulzer) and, as a positive control, PQ1 (Ultradent), an etch-and-rinse adhesive. Each product was evaluated using the same hybrid resin composite, Z250 (3M ESPE). Testing was performed after 48 hours using a "non-trimming" microtensile test at a crosshead speed of 0.6 mm/minute. Sample size was five teeth per group, with the value for each tooth calculated by averaging the bond strengths of seven beams derived from it. Mean values in MPa (SD) for dentin were: Clearfil SE 81.6 (3.5),a Peak SE 80.3 (9.9),a PQ1 73.4 (4.9),a,b Optibond All-In-One 64.4 (5.9),b Clearfil S3 62.5 (2.2),b,c iBond 51.0 (4.0)c and Prompt L-Pop 33.9 (6.4).d Mean values in MPa (SD) for enamel were: PQ1 55.6 (2.5),a Clearfil SE 54.1 (5.4),a Prompt L-Pop 54.0 (5.4),a Peak SE 51.8 (1.5),a,b Clearfil S3 44.3 (5.2),b,c Optibond All-In-One 40.1 (2.1)c,d and iBond 33.8 (3.3).d (Values for each substrate with the same letter were not significantly different, one-way ANOVA, Tukey-Kramer Multiple Comparison Test, p<0.05.) Compared to the positive control, PQ1, only adhesives with self-etching primers, Clearfil SE and Peak SE, were as effective in bonding to both enamel and dentin. With the exception of Prompt L-Pop, scanning electron micrographs of the etched enamel surface produced by self-etching products indicated far less surface topography than conventional etching, even for self-etching primer systems producing the same bond strengths as the etch-and-rinse adhesive.

Download full-text PDF

Source
http://dx.doi.org/10.2341/07-43DOI Listing

Publication Analysis

Top Keywords

bond strengths
12
optibond all-in-one
12
prompt l-pop
12
dentin enamel
8
self-etching resins
8
clearfil kuraray
8
values mpa
8
clearfil
6
microtensile dentin
4
enamel bond
4

Similar Publications

Why does silicon have an indirect band gap?

Mater Horiz

January 2025

Department of Materials Science, University of Michigan, Ann Arbor, Michigan 48109, USA.

It is difficult to intuit how electronic structure features-such as band gap magnitude, location of band extrema, effective masses, -arise from the underlying crystal chemistry of a material. Here we present a strategy to distill sparse and chemically-interpretable tight-binding models from density functional theory calculations, enabling us to interpret how multiple orbital interactions in a 3D crystal conspire to shape the overall band structure. Applying this process to silicon, we show that its indirect gap arises from a competition between first and second nearest-neighbor bonds-where second nearest-neighbor interactions pull the conduction band down from Γ to X in a cosine shape, but the first nearest-neighbor bonds push the band up near X, resulting in the characteristic dip of the silicon conduction band.

View Article and Find Full Text PDF

The CFH group can act as a hydrogen bond donor, serving as a potential surrogate for OH or SH groups but with a weaker hydrogen bond donation ability. Here, we describe a series of CFH group-containing moieties that facilitate hydrogen bond interactions. We survey hydrogen bond donation ability using several established methods, including H NMR-based hydrogen bond acidity determination, UV-vis spectroscopy titration with Reichardt's dye, and H NMR titration using tri--butylphosphine oxide as a hydrogen bond acceptor.

View Article and Find Full Text PDF

Effect of different root canal irrigation regimes microbubble emulsion (MBE) via riboflavin photosensitizer (RFP), cerium oxide (CeO) nanoparticles (NPs), and Nd: YAP laser on antibacterial efficiency, microhardness (MH), smear layer (SL) removal efficacy, and push-out bond strength (PBS) of AH plus sealer to canal dentin. Sixty single-rooted teeth were selected, disinfected, and categorized into four groups based on the type of disinfection. Following disinfection, a pair of samples were randomly selected and visualized under scanning electron microscope (SEM) for SL evaluation.

View Article and Find Full Text PDF

After cyclo-pentazolate anion, a 5/6 fused structure of N is constructed, and four novel nitrogen-rich ionic compounds are assembled on its basis. The results of the quantum calculations revealed an uneven distribution of electrons on cyclo-N , with significant charge density near the N5/N9 atoms and an ADCH charge of -0.425.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!