[Biventricular stimulation for AV block].

Herzschrittmacherther Elektrophysiol

Universitätsklinikum Giessen und Marburg, Standort Marburg Klinik für Innere Medizin - Kardiologie, Angiologie und Kardioprävention, Marburg.

Published: March 2008

Since the establishment of cardiac resynchronization therapy in left bundle branch block and mechanical asynchrony, the adverse effects of right ventricular apical pacing have gained increasing scientific interest. The sequelae of "iatrogenic desynchronization" on cardiac structure and function as well as on patients' prognosis could be well documented. "Minimally desynchronizing" stimulation strategies could be an alternative for patients needing ventricular pacing. The search for hemodynamically more advantageous alternative right ventricular pacing sites has failed so far to deliver well validated results, and due to the somewhat higher lead dislodgment rates pure left ventricular pacing cannot be recommended, at least not in pacemaker-dependent patients. Hence there is the question for primary biventricular stimulation in patients with AV block. The results of several biventricular studies with limited numbers of patients have been promising with respect to structural and functional surrogate endpoints. Two major controlled prospective and prognostically orientated studies, the BIOPACE study and the BLOCK-HF study, are currently underway and will report results in the next few years. According to the actual guidelines of the European Society of Cardiology (ESC) the implantation of a biventricular system is recommended in patients with AV block even without left bundle branch block (Class IIa, evidence level C) if they fulfill the remaining criteria that justify the implantation of a biventricular system. According to the guidelines for pacemaker therapy of the German Cardiac Society (GCS) biventricular pacing can be considered in these patients. Both societies do expressly permit the implantation of biventricular systems with ICD backup if indicated.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00399-008-0599-8DOI Listing

Publication Analysis

Top Keywords

ventricular pacing
12
implantation biventricular
12
left bundle
8
bundle branch
8
branch block
8
patients block
8
biventricular system
8
patients
6
biventricular
6
pacing
5

Similar Publications

Introduction: Haemodynamic atrioventricular delay (AVD) optimisation has primarily focussed on signals that are not easy to acquire from a pacing system itself, such as invasive left ventricular catheterisation or arterial blood pressure (ABP). In this study, standard clinical central venous pressure (CVP) signals are tested as a potential alternative.

Methods: Sixteen patients with a temporary pacemaker after cardiac surgery were studied.

View Article and Find Full Text PDF

A 72-year-old woman underwent left bundle branch area pacing, and subsequent transthoracic echocardiography demonstrated potential septal lead perforation. Transesophageal echocardiography revealed an intracardiac mass, which resolved with anticoagulation. This case highlights left ventricular thrombus as a potential complication of septal lead perforation.

View Article and Find Full Text PDF

Objective: To evaluate systematically the feasibility and effectiveness of His Bundle Pacing (HBP) for cardiac resynchronization therapy.

Methods: A comprehensive search was conducted in PubMed, EMbase, WOS, Cochrane Library, Medline, and SinoMed for studies published between December 2003 and December 2023. Primary clinical outcomes included implantation success, QRS wave duration, pacing threshold, left ventricular ejection fraction (LVEF), left ventricular end-diastolic diameter (LVEDD), New York Heart Association (NYHA) cardiac function class, and complications.

View Article and Find Full Text PDF

Cardiac strangulation with chronic ab-extrinseco occlusion of the left-circumflex artery from an epicardial lead: a case report.

Eur Heart J Case Rep

January 2025

Department of Radiological and Hematological Sciences, Section of Radiology, Università Cattolica del Sacro Cuore, Largo Agostino Gemelli 8 - 00168 Rome, Italy.

Background: Cardiac strangulation (CS) from epicardial pacing leads (EPLs) is a rare and potentially lethal mechanical complication associated with epicardial pacemaker (PM) implantation.

Case Summary: We report a case of a 44-year-old-female patient presenting with chest and left shoulder pain in the absence of reported trauma with history of congenital atrioventricular block treated with epicardial PM implantation during the childhood and subsequent transvenous reimplantation over the years. Troponin I resulted within normal values and ECG, transthoracic echocardiography and chest X-ray documented no acute cardiopulmonary findings.

View Article and Find Full Text PDF

Background: Programmed electrical stimulation (PES) is an essential part of ventricular tachycardia (VT) ablation procedures, but VT is not always inducible, usually for reasons that are not clear.

Objectives: This study sought to review pacing site-specific failure of PES to induce scar-related VT and to provide a potential mechanistic explanation of the phenomena using a computer simulation.

Methods: Six patients in whom aggressive PES from traditional RV pacing sites failed to induce VT, but VT was easily inducible from a nontraditional site, were reviewed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!