Near-infrared calibration models were developed for the determination of content uniformity of pharmaceutical tablets containing 29.4% drug load for two dosage strengths (X and Y). Both dosage strengths have a circular geometry and the only difference is the size and weight. Strength X samples weigh approximately 425 mg with a diameter of 12 mm while strength Y samples, weigh approximately 1700 mg with a diameter of 20mm. Data used in this study were acquired from five NIR instruments manufactured by two different vendors. One of these spectrometers is a dispersive-based NIR system while the other four were Fourier transform (FT) based. The transferability of the optimized partial least-squares (PLS) calibration models developed on the primary instrument (A) located in a research facility was evaluated using spectral data acquired from secondary instruments B, C, D and E. Instruments B and E were located in the same research facility as spectrometer A while instruments C and D were located in a production facility 35 miles away. The same set of tablet samples were used to acquire spectral data from all instruments. This scenario mimics the conventional pharmaceutical technology transfer from research and development to production. Direct cross-instrument prediction without standardization was performed between the primary and each secondary instrument to evaluate the robustness of the primary instrument calibration model. For the strength Y samples, this approach was successful for data acquired on instruments B, C, and D producing root mean square error of prediction (RMSEP) of 1.05, 1.05, and 1.22%, respectively. However for instrument E data, this approach was not successful producing an RMSEP value of 3.40%. A similar deterioration was observed for the strength X samples, with RMSEP values of 2.78, 5.54, 3.40, and 5.78% corresponding to spectral data acquired on instruments B, C, D, and E, respectively. To minimize the effect of instrument variability, calibration transfer techniques such as piecewise direct standardization (PDS) and wavelet hybrid direct standardization (WHDS) were used. The PDS approach, the RMSEP values for strength X samples were lowered to 1.22, 1.12, 1.19, and 1.08% for instruments B, C, D, and E, respectively. Similar improvements were obtained using the WHDS approach with RMSEP values of 1.36, 1.42, 1.36, and 0.98% corresponding to instruments B, C, D, and E, respectively.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.aca.2008.02.016DOI Listing

Publication Analysis

Top Keywords

strength samples
20
spectral data
12
data acquired
12
rmsep values
12
instruments
9
content uniformity
8
pharmaceutical tablets
8
calibration transfer
8
calibration models
8
models developed
8

Similar Publications

Background: Spinal cord injury/disease (SCI/D) profoundly affects both sexuality and urinary function. Catheterization is often necessary to manage bladder voiding and it can interfere with sexual activity.

Aim: We aim to investigate the effect of the bladder evacuation method on sexual activity in women with chronic SCI/D.

View Article and Find Full Text PDF

This study is aimed at evaluating the quality and safety of two traditional fermented dairy products commonly found in Lebanon (Ambarees and Kishk in its dry and wet forms) by detecting foodborne pathogens and indicator microorganisms. Additionally, it seeks to identify the strengths, weaknesses, opportunities, and threats to quality and the production level. A total of 58 random samples (duplicated) including goat milk ( = 16), dry Kishk ( = 8), wet Kishk ( = 8), and Ambarees ( = 26) were collected from individuals who both farm and process these products.

View Article and Find Full Text PDF

Transcutaneous Electrical Nerve Stimulation (TENS) and Electronic Muscle Stimulation (EMS) are non-invasive therapies widely used for pain relief and neuromuscular adaptation. However, the clinical research supporting the efficacy of TENS in chronic pain management is limited by significant methodological flaws, including small sample sizes and inconsistent reporting of stimulation parameters. TENS modulates pain perception through various techniques, targeting specific nerve fibers and pain pathways.

View Article and Find Full Text PDF

Purpose: To provide a fast quantitative imaging approach for a 0.55T scanner, where signal-to-noise ratio is limited by the field strength and k-space sampling speed is limited by a lower specification gradient system.

Methods: We adapted the three-dimensional spiral projection imaging MR fingerprinting approach to 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!