Diadenosine polyphosphates (Ap(n)A) are released by degranulating platelets and high, local concentrations may form at sites of platelet activation. Radial artery grafts, now often used alongside the internal mammary artery in coronary artery bypass surgery, are particularly reactive to several vasoconstrictors but the response to Ap(n)A has not been investigated. This study compared the vasoconstrictor activity of Ap(n)A in human radial artery with other vessels commonly used as bypass grafts. Radial artery demonstrated robust concentration-dependent vasoconstriction to Ap(n)A (n=4-6) at concentrations in the micromolar range. In contrast, average responses in internal mammary artery were negligible. Cross-desensitization revealed that Ap(n)A-mediated vasoconstriction occurred via an alphabetamethyleneATP-sensitive receptor. Responses to both Ap(5)A and alphabetamethyleneATP were inhibited by suramin but were insensitive to the P2X(1) receptor antagonist 8,8'-[Carbonylbis(imino-4,1-phenylenecarbonylimino-4,1-phenylenecarbonylimino)]bis-1,3,5-naphthalenetrisulfonic acid (NF279). Pyridoxalphosphate-6-azophenyl-2',4'-disulphonic acid (PPADS) enhanced responses to Ap(5)A. Similar responses were obtained in saphenous vein. In conclusion, diadenosine polyphosphates contract radial artery and saphenous vein by an as yet uncharacterized P2X receptor but have only limited activity in internal mammary artery. The selective activity of diadenosine polyphosphates in radial artery would implicate them as potential mediators of post-operative contraction in this graft.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.vph.2008.01.005DOI Listing

Publication Analysis

Top Keywords

radial artery
20
diadenosine polyphosphates
16
internal mammary
12
mammary artery
12
artery
10
coronary artery
8
artery bypass
8
bypass grafts
8
responses ap5a
8
saphenous vein
8

Similar Publications

Background: This is a single-centre prospective observational study examining radial access in 62 Prostatic Artery Embolisation (PAE) procedures. Evaluation of left radial artery diameter using high frequency ultrasound before and after administration of sublingual glycerl trinitrate (GTN). Pre-procedure questionnaires calculating symptom severity score compared with post-procedure.

View Article and Find Full Text PDF

Mechanical properties of the bicipital aponeurosis.

J Mech Behav Biomed Mater

December 2024

School of Engineering, University of Guelph, Guelph, Ontario, Canada. Electronic address:

As a biarticular muscle, the biceps brachii both supinates the forearm and flexes the elbow and shoulder, thus allowing the upper limb to perform a variety of activities of daily living (ADL). The biceps brachii originates on the coracoid apex as well as the supraglenoid tubercle and inserts on the radial tuberosity. At the distal end, the bicipital aponeurosis (BA) provides a transition of the biceps tendon into the antebrachial fascia.

View Article and Find Full Text PDF

Penile Reconstruction with Radial Forearm Free Flap-Present State of the Art.

Indian J Plast Surg

December 2024

Department of Plastic and Reconstructive Surgery, Amrita Hospital, Faridabad, Haryana, India.

 Patients with congenital or acquired penile defects face significant psychological trauma. Various methods for penile reconstruction have been described of which the free radial artery forearm flap using the tube-within-tube design is found to be the most commonly used. We have assimilated the best practices described at different times in our bid to standardize the technique and have strived to make it reproducible.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!