Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Spectrophotometry of cerebrospinal fluid (CSF) for bilirubin is the recommended method for investigation in suspected cases of subarachnoid haemorrhage (SAH), when a computed tomography (CT) of the head is negative for blood. There is a potential need for a simpler alternative. Measurement of CSF ferritin might fulfil this need.
Method: We have measured ferritin in the CSF from 252 patients with suspected SAH who were negative on a CT of the head for blood, recruited on a consecutive intention to recruit basis from four centres. CSF spectrophotometry was performed on all samples. A positive outcome was taken as an aneurysm found on angiography that was treated or a discharge diagnosis of non-aneurysmal SAH.
Results: A final diagnosis of aneurysmal SAH was made in six patients, an arteriovenous malformation in one and non-aneurysmal SAH in nine. Receiver operating characteristic (ROC) analysis showed that at 6.4 microg/L, sensitivity, specificity, positive and negative predictive values were 1.0, 0.48, 0.12 and 1.0, respectively. At 12 microg/L, these values were 0.81, 0.91, 0.38 and 0.98, respectively.
Conclusions: At an appropriate negative predictive value (1.0) for a rule-out test, ferritin has too low a specificity to function as a stand-alone test and we cannot recommend it as an initial screen to be followed by spectrophotometry.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1258/acb.2007.007043 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!