Three-dimensional vision based on a combination of gray-code and phase-shift light projection: analysis and compensation of the systematic errors.

Appl Opt

Instituto Nazionale Fisica della Materia and the Dipartimento di Elettronica per l'Automazione, Università degli Studi di Brescia, Via Branze 38, I-25123 Brescia, Italy.

Published: November 1999

A combination of phase-shift with gray-code light projection into a three-dimensional vision system based on the projection of structured light is presented. The gray-code method is exploited to detect without ambiguity even marked surface discontinuities, whereas the phase-shift technique allows the measurement of fine surface details. The system shows excellent linearity. An overall mean value of the measurement error equal to 40 microm, with a variability of approximately +/-35 microm, corresponding to 0.06% of full scale, has been estimated. The implementation of the technique is discussed, the analysis of the systematic errors is presented in detail, and the calibration procedure designed to determine the optimal setting of the measurement parameters is illustrated.

Download full-text PDF

Source
http://dx.doi.org/10.1364/ao.38.006565DOI Listing

Publication Analysis