Test-retest reliability of spatial and temporal gait parameters of people with Alzheimer's disease.

Gait Posture

Musculoskeletal Research Centre, Faculty of Health Sciences, La Trobe University, Bundoora, Australia.

Published: October 2008

The reliability of measures of walking in people with Alzheimer's disease (AD) has not been established despite the increased variability of their walking compared to control groups. The purpose of this study was to examine the test-retest reliability of temporal and spatial gait measurements in community dwelling people with AD. Ten males and 10 females with AD completed 10 walks on an instrumented walkway at self-selected comfortable speed on two occasions, 1 week apart. Data from 10 walks for each subject for each session were averaged and test-retest reliability of velocity, cadence, step length, stride length, step width, toe in/out angle, swing and stance times was measured using intraclass correlation coefficients (ICCs) of the type (3, 1). Coefficients of variation (CV) of method error were calculated to determine between-trial variability and the minimum detectable change (MDC) was calculated to indicate the difference in scores required to show a true change. This analysis was repeated for averages of the first three walks for each subject at each session. ICCs were found to be high (>0.86) for all gait parameters using both 10 and three walks, indicating high test-retest reliability for these measures in people with AD with as few as three walks. Measures of support base and toe in/out angle, however, had higher CV, even with increased numbers of walks, suggesting that only large changes in these parameters can be detected. MDC values suggested that demonstration of real change in gait measures is feasible in this population.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.gaitpost.2008.01.007DOI Listing

Publication Analysis

Top Keywords

test-retest reliability
16
three walks
12
gait parameters
8
people alzheimer's
8
alzheimer's disease
8
reliability measures
8
walks subject
8
subject session
8
toe in/out
8
in/out angle
8

Similar Publications

Objective: To determine the correlation among five different types of tumor regression grading (TRG) systems. Test-retest reliability analyses were conducted at two time points to assess the internal validity and consistency of these five TRG systems.

Methods: A test-retest study was performed in 34 pathologically confirmed rectal adenocarcinoma specimens.

View Article and Find Full Text PDF

Utility of a C-Spirulina Stable Isotope Gastric Emptying Breath Test in Diabetes Mellitus.

Neurogastroenterol Motil

January 2025

Division of Gastroenterology and Hepatology, Mayo Clinic, Rochester, Minnesota, USA.

Background: The carbon-13 spirulina gastric emptying breath test (GEBT) is approved to identify delayed, but not accelerated, gastric emptying (GE). We compared the utility of the GEBT to scintigraphy for diagnosing abnormal GE in patients with diabetes mellitus.

Methods: Twenty-eight patients with diabetes ate a 230-kcal test meal labeled with technetium 99 m and C-spirulina, after which 10 scintigraphic images and breath samples (baseline, 15, 30, 45, 60, 90, 120, 150, 180, 210, and 240 min) were collected on 2 occasions 1 week apart.

View Article and Find Full Text PDF

Purpose: The H reflex recruitment curve represents the gold standard for quantifying changes in spinal circuitries. However, there is no agreement on how many stimulations should be applied for each parameter. Thus, we explored the impact of varying the number of stimulations (3, 6, 9, 12 and 15 stimuli per intensity) on between-day reliability of soleus H reflex.

View Article and Find Full Text PDF

Deep Learning Superresolution for Simultaneous Multislice Parallel Imaging-Accelerated Knee MRI Using Arthroscopy Validation.

Radiology

January 2025

From the Department of Radiology, Division of Musculoskeletal Radiology, NYU Grossman School of Medicine, 660 1st Ave, 3rd Fl, Rm 313, New York, NY 10016 (S.S.W., J.V., R.K., E.H.P., J.F.); Department for Diagnostic and Interventional Radiology, Eberhard Karls University Tübingen, University Hospital Tübingen, Tübingen, Germany (S.S.W.); Department of Radiology, University Hospital Basel, Basel, Switzerland (J.V.); Department of Radiology, Hospital do Coraçao, São Paulo, Brazil (T.C.R.); Academic Surgical Unit, South West London Elective Orthopaedic Centre (SWLEOC), London, United Kingdom (D.D.); Department of Radiology, Balgrist University Hospital, Zurich, Switzerland (B.F.); Department of Radiology, Jeonbuk National University Hospital, Jeonju, Republic of Korea (E.H.P.); Research Institute of Clinical Medicine of Jeonbuk National University, Biomedical Research Institute of Jeonbuk National University Hospital, Jeonju, Republic of Korea (E.H.P.); Medscanlagos Radiology, Cabo Frio, Brazil (A.S.); Centre for Data Analytics, Bond University, Gold Coast, Australia (S.E.S.); Siemens Healthineers AG, Erlangen, Germany (I.B.); and Siemens Medical Solutions USA, Malvern, Pa (G.K.).

Background Deep learning (DL) methods can improve accelerated MRI but require validation against an independent reference standard to ensure robustness and accuracy. Purpose To validate the diagnostic performance of twofold-simultaneous-multislice (SMSx2) twofold-parallel-imaging (PIx2)-accelerated DL superresolution MRI in the knee against conventional SMSx2-PIx2-accelerated MRI using arthroscopy as the reference standard. Materials and Methods Adults with painful knee conditions were prospectively enrolled from December 2021 to October 2022.

View Article and Find Full Text PDF

Exploration of the dynamics of otic capsule and intracochlear pressure: Numerical insights with experimental validation.

J Acoust Soc Am

January 2025

Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Zurich, University of Zurich, Zurich, Switzerland.

The otic capsule and surrounding temporal bone exhibit complex 3D motion influenced by frequency and location of the bone conduction stimulus. The resultant correlation with the intracochlear pressure is not sufficiently understood, thus is the focus of this study, both experimentally and numerically. Experiments were conducted on six temporal bones from three cadaver heads, with BC hearing aid stimulation applied at the mastoid and classical BAHA locations across 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!