Objective: Cystatin C-and creatinine-based methods were compared with (99m)-technetium-diethylene-triamine-penta-acetic acid ((99m)Tc-DTPA) plasma clearance (isotopic glomerular filtration rate [iGFR]) for detecting declining renal function.

Research Design And Methods: Glomerular filtration rate (GFR) was monitored over a mean of 10.1 years in 85 subjects with type 1 diabetes (with an average of 5.6 measurements per individual). Baseline mean +/- SD iGFR of the cohort was 106.1 +/- 2.6 ml/min per 1.73 m(2). The rates of decline in GFR (DeltaGFR) were derived using linear regression.

Results: In 19 of 85 subjects with declining renal function (i.e., DeltaiGFR >3.3 ml/min per 1.73 m(2) per year), DeltaGFR (ml/min per 1.73 m(2) per year) was 6.5 by iGFR, 4.2 by 10(4)/creatinine, 3.6 by Cockcroft-Gault formula, 3.4 by the Modification of Diet in Renal Disease (MDRD)-6 equation, and 3.5 by the MDRD-4 variable equation (P < 0.01 vs. iGFR). In comparison, DeltaGFR was 6.1 using the formula Cys-GFR = (86.7/cystatin C concentration) - 4.2 (not significant).

Conclusions: Cystatin C was more accurate in detecting decline in renal function than creatinine-based methods in this population of subjects with type 1 diabetes and a normal mean baseline GFR.

Download full-text PDF

Source
http://dx.doi.org/10.2337/dc07-1588DOI Listing

Publication Analysis

Top Keywords

creatinine-based methods
12
declining renal
12
renal function
12
type diabetes
12
ml/min 173
12
cystatin accurate
8
detecting declining
8
glomerular filtration
8
filtration rate
8
subjects type
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!