Background: The Laryngeal Mask Airway-Unique (LMAU) and CobraPLA (Cobra Perilaryngeal Airway) are supraglottic airway devices. There are no published studies comparing these devices in children breathing with pressure controlled ventilation (PCV).
Methods: Eighty pediatric patients, scheduled for elective general surgery of short duration, were randomly assigned to have either a CobraPLA or a LMAU used for airway management using PCV. We compared the devices with respect to (i) ability to form an effective cuff seal, (ii) oxygenation, (iii) endtidal carbon dioxide level, (iv) time to achieve an effective airway, (v) airway interventions required for insertion, (vi) fiberoptic score, (vii) respiratory variables and (vii) adverse events.
Results: Cuff seal pressure was significantly higher for CobraPLA (27.08 +/- 4.15 cmH(2)O) than for LMAU (20.91 +/- 2.47 cmH(2)O). Oxygenation was similar in both groups while the mean endtidal CO(2) in the CobraPLA group was significantly higher than in the LMAU group (36.47 +/- 1.93 mmHg vs 34.71 +/- 3.05 mmHg, P = 0.021). Time and ease of insertion were similar, with CobraPLA requiring more frequent jaw lift and LMAU requiring more frequent adjustment of the head and neck to achieve a proper position. Fiberoptic scores were excellent with both devices. Respiratory variables were similar with the exception that the plateau pressure and mean peak pressures were significantly lower with CobraPLA. There was a low rate of blood mucosal staining of the devices. No patient in either group reported a sore throat.
Conclusions: Both devices appear to be safe and effective in establishing an adequate airway in healthy children undergoing surgery of short duration with PCV.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1460-9592.2008.02449.x | DOI Listing |
Medicine (Baltimore)
June 2019
Department of Anesthesiology, Xinqiao Hospital of Army Military Medical University, Shapingba District, Chongqing, China.
Cobra Perilaryngeal Airway (Cobra-PLA) is a relatively new single-use supraglottic device employed during general anesthesia. This meta-analysis includes randomized controlled trials (RCTs) yielding extensive comparison results among Cobra-PLA, Laryngeal Mask Airway (LMA)-Classic, and LMA-Unique.Two authors performed searches in EMBASE, CENTRAL, PubMed, and ScienceDirect to identify RCTs that compared Cobra-PLA with LMA-Classic and with LMA-Unique in patients undergoing general anesthesia.
View Article and Find Full Text PDFAnesth Analg
September 2017
From the *Department of Anesthesiology, the Eye, Ear, Nose and Throat Hospital of Fudan University, Shanghai Medical College of Fudan University, Shanghai, China; and †Department of Oro-maxillofacial Head and Neck Oncology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai Key Laboratory of Stomatology, Shanghai, China.
The complication rate and efficacy of the Cobra Perilaryngeal Airway (CobraPLA) and laryngeal mask airways (LMAs®) have been evaluated in the published literature, but the conclusions have been inconsistent. The aim of this systematic review and meta-analysis was thus to assess the performance of the CobraPLA and LMAs under general anesthesia. We searched PubMed, Embase, and the Cochrane Library for randomized controlled trials comparing the CobraPLA with LMAs under general anesthesia.
View Article and Find Full Text PDFTanaffos
July 2015
Department of Public Health, Qazvin University of Medical Sciences, Qazvin, Iran.
Background: This study aimed to evaluate the applicability of Cobra perilaryngeal airway (Cobra PLA™) for obese patients under general anesthesia and also to compare the results with those of classic laryngeal mask airway (LMA™).
Materials And Methods: Seventy-three overweight and obese patients were included in this study. The patients were randomly assigned to LMA™ or Cobra PLA™ groups.
Acta Cir Bras
January 2015
Department of Anesthesiology and Reanimation, Medical Faculty, Çanakkale Onsekiz Mart University, Çanakkale, Turkey.
Purpose: To evaluate the applicability and airway management capacity of v-gel® and Cobra PLA in rabbit anaesthesia during assisted (AV) or controlled ventilation (CV).
Methods: This study was carried out in 44 adult New Zealand white rabbit. Baseline arterial pH, PaCO2 and PaO2 values were recorded.
Saudi J Anaesth
October 2014
Department of Anesthesia, Faculty of Medicine, Cairo University, Giza, Egypt.
Background: One of the methods proposed in cases of difficult airway management in children is using a supraglottic airway device as a conduit for tracheal intubation. The aim of this study was to compare the efficacy of the Air-Q Intubating Laryngeal Airway (Air-Q) and the Cobra Perilaryngeal Airway (CobraPLA) to function as a conduit for fiber optic-guided tracheal intubation in pediatric patients.
Materials And Methods: A total of 60 children with ages ranging from 1 to 6 years, undergoing elective surgery, were randomized to have their airway managed with either an Air-Q or CobraPLA.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!