Objectives: To identify functional aortic regurgitation (FAR) determinants in patients with ascending thoracic aortic aneurysm (ATAA) and surgically confirmed normal aortic valve anatomy.
Design: Case-control study.
Setting: Non-invasive Cardiology and Cardiac Surgery Department.
Patients: Eighty-nine patients with ATAA and varying degrees of FAR undergoing surgery, 40 age-matched patients with ATAA without aortic regurgitation and 20 normal control subjects.
Interventions: Doppler and two-dimensional transoesophageal echocardiography.
Main Outcome Measures: Vena contracta (VC) of aortic regurgitant jet, diastolic tented area and coaptation height (CH) of aortic valve leaflets, aortic dimension indexes-Valsalva sinus, sinotubular junction (STJ), tubular tract, annulus (A), STJ/A ratio.
Results: When VC was used, a wide range of FAR was seen (mean (SD) 5.59 (2.59) mm, ranging from 2 to 13 mm). Of the variables tested, the most strongly associated with FAR severity in multivariate analysis was diastolic leaflet tenting, measured as CH (R(2) = 0.69) (sensitivity 98%, specificity 95% using a cut-off value of CH > or =1.1 cm). In turn, the diastolic leaflet tenting was strongly identified by the STJ/A ratio (sensitivity 87%, specificity 71% using a cut-off value of STJ/A >1.66).
Conclusion: The diastolic tenting of aortic leaflets is strongly related to FAR severity in patients with ATAA. The mismatch of STJ/A is significantly associated with diastolic leaflet tenting and its correlated valve regurgitation, independently of the actual ATAA dimension. These findings provide new insight into the mechanism of FAR arising from ATAA.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1136/hrt.2007.134494 | DOI Listing |
J Thorac Cardiovasc Surg
January 2025
Department of Surgery, Division of Vascular Surgery, University of Maryland School of Medicine.
Objective: We present our experience with endovascular Bentall procedure (Endo-Bentall) using a modular valve conduit (Endo-Bentall) in high-risk patients with aortic root pathologies.
Methods: The physician constructed Endo-Bentall device is composed of a self-expanding transcatheter aortic valve (TAVR), aortic endovascular stent graft (TEVAR), and two wire-reinforced fenestrations for coronary artery stenting. The TAVR valve is sutured into an appropriately sized TEVAR graft.
Clin Imaging
January 2025
Institute of Clinical sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden; Dept of Pediatric Radiology, The Queen Silvia Children's Hospital, Region Västra Götaland, Sahlgrenska University Hospital, Gothenburg, Sweden.
Background: Congenital heart diseases (CHDs) are common birth defects. This work presents over four years of clinical experience of 4D flow cardiovascular magnetic resonance (CMR), highlighting its value for pediatric CHD.
Methods: Children with various CHD diagnoses (n = 298) were examined on a 1.
Indian J Thorac Cardiovasc Surg
February 2025
Department of Cardiovascular Surgery, Abderrahmen Mami Pneumology and Phthisiology Hospital, Ariana, Tunisia.
Infective endocarditis (IE) in children is a rare entity which presents a high rate of events during follow-up. Congenital heart disease, i particular ventricular septal defect (VSD), is the main predisposing condition to IE at those ages. The long-term risk of IE is of concern and whose follow-up can be complicated by a relapse of IE and reintervention.
View Article and Find Full Text PDFAm J Transl Res
December 2024
Department of Cardiac Surgery, The Second Hospital of Hebei Medical University Shijiazhuang 050000, Hebei, China.
Objective: To identify the risk factors associated with moderate to severe perivalvular leakage (PVL) after transcatheter aortic valve replacement (TAVR) and to construct a prediction model for this risk.
Methods: A retrospective analysis was conducted on 128 patients with severe aortic stenosis who had received TAVR in The Second Hospital of Hebei Medical University from January 2019 to January 2024. The length of the aortic regurgitation bundle and annular circumference ratio were measured by transesophageal echocardiography immediately after the valve implantation.
Kardiol Pol
January 2025
2nd Department of Radiology, Medical University of Lublin, Lublin, Poland.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!