Porous polyethylene (Medpor) orbital implants with primary acellular dermis patch grafts.

Orbit

Wolverhampton and Midland Counties Eye Infirmary, Wolverhampton, West Midlands, UK.

Published: April 2008

Purpose: To evaluate the results of the porous polyethylene (Medpor) orbital implantation technique combined with the use of a primary patch graft of acellular dermis.

Methods: The study design was a retrospective, non-comparative single surgeon case series of 27 patients. The Medpor orbital implant was placed with a primary anterior sub-Tenon's acellular dermis patch after evisceration (23/27), enucleation (2/27) or implant exchange/secondary implant procedure (2/27) over a period of 3 years. Risk factors for dehiscence/complications were defined as trauma, infection, inflammation, previous ocular surgery, radiotherapy, secondary orbital implantation, and removal of extruding implants. The primary outcome measure was the development of implant exposure. Other complications were also recorded, including postoperative conjunctival wound dehiscence.

Results: Twenty-five patients (93%) had more than 2 risk factors. Mean follow-up time was 22 months (median 24 months, range 4-34 months). Three (11%) patients needed further intervention, which included pyogenic granuloma excision (1) and fornix formation (1). Conjunctival wound dehiscence followed by implant exposure occurred in 1 of 27 eyes (3.7%). The cosmetic appearance was satisfactory in 26/27 patients.

Conclusions: Our results with primary acellular dermis grafts when coupled with Medpor orbital implantation are encouraging.

Download full-text PDF

Source
http://dx.doi.org/10.1080/01676830601168900DOI Listing

Publication Analysis

Top Keywords

medpor orbital
16
acellular dermis
12
orbital implantation
12
porous polyethylene
8
polyethylene medpor
8
implants primary
8
primary acellular
8
dermis patch
8
risk factors
8
implant exposure
8

Similar Publications

Article Synopsis
  • Medpor implantation significantly improves extraocular muscle function and reduces symptoms like eye movement disorders and diplopia in patients after orbital wall fractures.
  • The study showed a strong correlation between the degree of eyeball enophthalmos and the fracture area before surgery, which diminished post-operation.
  • Patients who had surgery within three weeks of the injury experienced higher recovery rates for muscle restrictions and paralysis compared to those who waited longer.
View Article and Find Full Text PDF

Aim: To compare the exposure rate, infection rate, percentage of enhancement, and success rate between Medpor and the three-dimensional printed polyethylene (3DP-PE) orbital implant in a preliminary report.

Methods: This prospective, randomized, equivalence, controlled trial was conducted at two institutes. The equivalent margin was ±10%.

View Article and Find Full Text PDF
Article Synopsis
  • - The paper discusses using a new method for fixing zygomatic malposition and orbital floor fractures with hydrated acellular dermal matrix (ADM) after traditional implants failed for a 27-year-old woman with ongoing facial issues from trauma.
  • - The surgery used ADM for volume correction and structural support, successfully addressing problems like enophthalmos, facial contour depression, and restoring the patient’s facial symmetry and eye functionality.
  • - Results showed that this ADM method is a reliable alternative to standard bone grafts and implants, paving the way for its broader use in complex facial reconstructive surgery after trauma.
View Article and Find Full Text PDF
Article Synopsis
  • * The surgery involved a collaboration between head and neck surgeons and oculofacial plastic surgeons, employing techniques like canthotomy and orbitotomy for tumor excision and reconstruction with a Medpor implant.
  • * Post-surgery, the patient showed positive healing progress with no visual issues, and the coordinated approach ensured both aesthetic and functional restoration of the midface, achieving near symmetry in facial structure.
View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to evaluate the effectiveness and safety of a new surgical approach combining medial orbital wall osteotomy with the implantation of Medpor material for treating orbital hypertelorism.
  • Researchers conducted a retrospective analysis on patients who underwent this surgery from 2010 to 2019, assessing long-term outcomes and any surgery-related complications.
  • Results showed that all four patients (3 males, 1 female) were satisfied after 24 months, with no serious complications such as vision loss or implant rejection, indicating the procedure's safety and effectiveness.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!