Background: Comparison of neurological parameters in patients undergoing prosthetic heart valve replacement with two operating techniques-either cardioplegic arrest of the heart under hypothermic cardiopulmonary bypass (CPB) or the heart beating on normothermic bypass, with or without cross-clamping the aorta, without cardioplegic arrest. methods: Fifty valvular surgery patients were randomly assigned into three groups. Sixteen patients underwent beating heart valve replacement with normothermic bypass without cross-clamping the aorta, 17 patients underwent the same procedure with cross-clamping the aorta and retrograde coronary sinus perfusion, and the remaining 17 patients had conventional surgery with hypothermic bypass and cardioplegic arrest.

Results: Two-channel electroencephalography (EEG) was recorded to assess changes in cerebral cortical synaptic activity and 95% spectral edge frequency values were recorded continuously. Bispectral monitoring was used to measure the depth of anesthesia. Blood flow rates in middle cerebral artery (MCA) were measured by transcranial Doppler (TCD). Reduction in spectral edge frequency (>50%) or bispectral index (BIS) (<20) or transcranial Doppler flow velocity (>50%) was detected in four patients in Group 1, five patients in Group 2, and three patients in Group 3. BIS or EEG values never reached zero, which indicates isoelectric silence during surgery. Gross neurological examinations were normal in all patients postoperatively.

Conclusion: There is no difference regarding neurological monitoring results between on-pump beating heart and hypothermic arrested heart valve replacement surgery. Also no significant difference was encountered among the groups regarding the clinical outcomes.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1540-8191.2007.00536.xDOI Listing

Publication Analysis

Top Keywords

heart valve
16
valve replacement
16
beating heart
12
cross-clamping aorta
12
patients group
12
patients
9
on-pump beating
8
heart
8
hypothermic arrested
8
arrested heart
8

Similar Publications

Purpose Of Review: This review aims to explore the complex interplay between atrial functional mitral regurgitation (AFMR), atrial fibrillation (AF), and heart failure with preserved ejection fraction (HFpEF). The goal is to define these conditions, examine their underlying mechanisms, and discuss treatment perspectives, particularly addressing diagnostic challenges.

Recent Findings: Recent research highlights the rising prevalence of AFMR, now accounting for nearly one-third of significant mitral regurgitation cases.

View Article and Find Full Text PDF

Background: Evidence regarding the incidence of prosthesis-patient mismatch (PPM) and long-term mortality after transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve stenosis (AS) is scarce.

Objectives: This study sought to assess the incidence and prognostic impact of PPM after TAVR for bicuspid AS compared with that for tricuspid AS.

Methods: In total, 7,393 patients who underwent TAVR were prospectively enrolled in the OCEAN-TAVI (Optimized Catheter Valvular Intervention Transcatheter Aortic Valve Implantation) registry, an ongoing Japanese, multicenter registry.

View Article and Find Full Text PDF

Background: Left ventricular (LV) volumes can be calculated from various linear, monoplane, and multiplane echocardiographic methods, and the same method can be applied to different imaging views. However, these methods and their variations have not been comprehensively evaluated against real-time 3-dimensional echocardiography (RT3D).

Hypothesis/objectives: To identify the LV volumetric approaches that produce the least bias and the best agreement with RT3D, and to assess interoperator reproducibility between an experienced and an inexperienced operator.

View Article and Find Full Text PDF