Purpose: Intracavitary high-dose-rate (HDR) brachytherapy (BT) for cervical cancer involves multiple applicator insertions. Our study addresses whether customized three-dimensional plans generated for the first insertion (using computed tomography [CT] planning) can be applied to subsequent insertions without significant changes in dose distributions if identical applicators are used.
Methods And Materials: Twenty-seven patients were treated with external-beam radiotherapy, platinum-based chemotherapy, and HDR BT. Either tandem and ovoids (TO, n=12) or tandem and ring (TR, n=15) applicators were used, based on clinical indications. Postimplant CT scans were acquired and custom plans generated for each insertion. Dose parameters for organs at risk (OARs) from the second insertion were retrospectively compared to those that would have been delivered using the initial plan.
Results: Overall, we observed a significant increase (p<0.038) in dose to International Commission on Radiation Units and Measurement points and 2cm(3) volumes of bladder and rectum when a single plan was used. The sigmoid and small bowel exhibited a more variable increase in dose. Applicator-specific results revealed a significant increase (p<0.030) to dose points and volumes for the rectum and bladder for TR applicators. Conversely, dose values from the more flexible TO did not show any significant trend, exhibiting large interpatient variations.
Conclusions: A duplication of planned dwell times and positions from one insertion to the next does not duplicate dose distributions in HDR cervix applications. A single plan used for an entire course of BT can result in significant increases to OAR doses for TR and unpredictable OAR doses for TO applicators. Treatment plans should be tailored for each insertion to reflect current applicator and anatomical geometry.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.brachy.2007.12.003 | DOI Listing |
J Cardiothorac Surg
January 2025
Semmelweis University Heart and Vascular Centre, Budapest, 1122, Hungary.
Background: Aortic dissection occurs rarely during pregnancy but carries a significantly high vital risk for both the mother and the fetus. Early diagnosis and treatment are critical for a successful outcome.
Case Presentation: A 32-year-old pregnant woman at 31 weeks of gestation began experiencing shortness of breath, chest pain, and palpitations, which were attributed to an anxiety disorder she had been previously diagnosed with.
BMC Pulm Med
January 2025
Department of Respiratory Medicine, Faculty of Life Sciences, Kumamoto University, Kumamoto 1-1-1 Honjo, Chuo-ku, 860-8556, Japan.
Background: Fibrotic types of interstitial lung abnormalities seen on high-resolution computed tomography scans, characterised by traction bronchiolectasis/bronchiectasis with or without honeycombing, are predictors of progression and poor prognostic factors of interstitial lung abnormalities. There are no reports on the clinical characteristics of fibrotic interstitial lung abnormalities on high-resolution computed tomography scans. Therefore, we aimed to examine these clinical characteristics and clarify the predictive factors of fibrotic interstitial lung abnormalities on high-resolution computed tomography scans.
View Article and Find Full Text PDFBMC Oral Health
January 2025
Department of Periodontics, Affiliated Hospital of Medical School, Nanjing Stomatological Hospital, Research Institute of Stomatology, Nanjing University, Nanjing, China.
Background: The severity of furcation involvement (FI) directly affected tooth prognosis and influenced treatment approaches. However, assessing, diagnosing, and treating molars with FI was complicated by anatomical and morphological variations. Cone-beam computed tomography (CBCT) enhanced diagnostic accuracy for detecting FI and measuring furcation defects.
View Article and Find Full Text PDFJ Nanobiotechnology
January 2025
Nurturing Center of Jiangsu Province for State Laboratory of AI Imaging & Interventional Radiology; Basic Medicine Research and Innovation Center of Ministry of Education, Medical School of Southeast University, 87 Dingjiaqiao, Nanjing, 210009, China.
Early diagnosis is critical for providing a timely window for effective therapy in pulmonary fibrosis (PF); however, achieving this remains a significant challenge. The distinct honeycombing patterns observed in computed tomography (CT) for the primary diagnosis of PF are typically only visible in patients with moderate to severe disease, often leading to missed opportunities for early intervention. In this study, we developed a nanoprobe designed to accumulate at fibroblastic foci and loaded with the CT sensitizer iodide to enable effective early diagnosis of PF.
View Article and Find Full Text PDFBMC Musculoskelet Disord
January 2025
Department of Orthopedics, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou Municipal Hospital, Gusu School, Nanjing Medical University, Suzhou, 215000, China.
Background: To analyze the effects of the positioning of a bolt in the femoral neck system (FNS) on the short-term outcomes of middle-aged and young adults with displaced femoral neck fractures (FNFs).
Methods: This was a retrospective study involving 114 middle-aged and young adults with displaced FNFs who were surgically treated with internal fixation via the FNS in the Department of Orthopedics, Suzhou Municipal Hospital, from December 2019 to January 2023. The degree of deviation of the central axis of the femoral head and neck from the tip of the bolt (W), the tip‒apex distance (TAD) and the length of femoral neck shortening (LFNS) were measured on postoperative X-ray and computed tomography (CT) scan images.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!