[New cardiac pacemakers].

Presse Med

Service de Cardiologie A, Hôtel-Dieu/CHRU, Rennes.

Published: June 1991

Because of the extraordinary technological progress made over the past years in pulse generators, the objective and indications of definitive cardiac pacing have greatly changed. All the different advantages are aimed at mimicking the electrophysiological and mechanical conditions of normal heart function. We have seen the development of: DDD mode dual chamber pacemakers, which in cases of AV block recreate normal AV synchrony; single chamber rate-responsive units piloted by an external captor responding to the organism's metabolic needs (intra-corporal vibrations resulting from exercise, respiratory rate, minute ventilation, QT interval, central temperature, SV O2...); they provide effective correction of atrial (AAI-R mode) or ventricular (VVI-R mode) chronotopic incompetencies often associated with chronic conduction disorders which make it impossible for patients paced in VVI or AAI mode to adapt heart rate to exercise level; and finally, "universal" pacemakers capable of pacing in all the single or dual chamber modes with rate responsiveness to one or several captors. These new pacemakers offer adaptability to the paced patient's needs as they vary throughout his lifetime. These units will probably be the "standard" cardiac pacemakers of the future.

Download full-text PDF

Source

Publication Analysis

Top Keywords

dual chamber
8
[new cardiac
4
cardiac pacemakers]
4
pacemakers] extraordinary
4
extraordinary technological
4
technological progress
4
progress years
4
years pulse
4
pulse generators
4
generators objective
4

Similar Publications

Epicardial Pacemaker Lead Related Cardiac Strangulation: The Importance of Early Recognition.

Pediatr Cardiol

January 2025

Cardiothoracic Department, Children's Health Ireland at Crumlin, Dublin, Ireland.

Lead strangulation is a dangerous complication of epicardial pacemaker insertion. This complication has been increasingly highlighted lately. Our institution has recently identified four cases over the past five years.

View Article and Find Full Text PDF

We present a dual isotope magneto-optical trap (MOT), simultaneous sub-Doppler laser cooling, and magnetic trapping of a spin-polarized K-K Bose-Fermi mixture realized in a single-chamber setup with an unenriched potassium dispenser as the source of atoms. We are able to magnetically confine more than 2.2 × 10 fermions ( = 9/2 ,  = 9/2) and 1.

View Article and Find Full Text PDF

A young man in his 30s presented to us with multiple episodes of syncope and exertional dyspnoea for the last 2 weeks. He was diagnosed with squamous cell carcinoma of the lower one-third of the oesophagus in 2021 for which he was treated with neoadjuvant chemoradiotherapy, followed by McKeown oesophagectomy. At 2-year follow-up, he had developed a soft tissue swelling in the scalp, which was diagnosed as a tumour recurrence and radiotherapy was initiated.

View Article and Find Full Text PDF

TiCT/Au NPs/PPy ternary heterostructure-based intra-capacitive self-powered sensor for DEHP detection.

J Hazard Mater

January 2025

Department of Analytical Chemistry, College of Chemistry, Jilin University, Changchun 130012, China. Electronic address:

Phthalate esters, particularly di(2-ethylhexyl) phthalate (DEHP), are widely used plasticizers found in various consumer products, posing significant environmental and health risks due to their endocrine-disrupting effects. In this study, a novel enzyme-free intra-capacitive biofuel cell self-powered sensor (ICBFC-SPS) was developed. The ICBFC-SPS integrated a ternary heterostructure-based capacitive anode and a cathode with a sensing interface into a single-chamber electrolytic cell.

View Article and Find Full Text PDF

Leadless Pacing: Current Status and Ongoing Developments.

Micromachines (Basel)

January 2025

Section of Electrophysiology, Division of Cardiology, Department of Internal Medicine, Rush University Medical Center, 1653 W. Congress, Chicago, IL 60612, USA.

Although significant strides have been made in cardiac pacing, the field is still evolving. While transvenous permanent pacing is highly effective in the management of bradyarrhythmias, it is not risk free and may result in significant morbidity and, rarely, mortality. Transvenous leads are often the weakest link in a pacing system.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!