Revision of Paine's technique for intraoperative ventricular puncture.

Surg Neurol

Department of Neurosurgery, Kyungpook National University, Daegu 700-721, South Korea.

Published: November 2008

Background: The aim of this study was to determine the ideal point for a ventricular puncture in pterional craniotomies.

Methods: Using a circle that had its center around the junction of the columns of the fornix and conforming to the surface of the frontal lobe on an axial computed tomography scan 2.5 cm superior to the lateral orbital roof, we simulated the introduction of a catheter perpendicular to the cortex by drawing the radii of the circle in 70 patients with an acute subarachnoid hemorrhage. The cortical point at which perpendicular puncture provides the best trajectory for ventricular access, traversing the least brain tissue and avoiding important brain structures, such as the head of the caudate nucleus, anterior limb of the internal capsule, and Broca's cortex in the dominant hemisphere, was measured.

Results: The new landmark was located at the point 44 +/- 4 mm anterior to the sylvian fissure on the level of 2.5 cm superior to the lateral orbital roof and was consistent regardless of the ventricular dimensions and sex. Clinical trial of the ventriculostomy in 32 patients with a ruptured aneurysm approved the new landmark.

Conclusions: An intraoperative ventriculostomy can be performed safely and reliably using the new landmark 2.5 cm superior to the lateral orbital roof and 4.5 cm anterior to the sylvian fissure in aneurysm surgery using a pterional craniotomy.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.surneu.2007.09.018DOI Listing

Publication Analysis

Top Keywords

superior lateral
12
lateral orbital
12
orbital roof
12
ventricular puncture
8
anterior sylvian
8
sylvian fissure
8
revision paine's
4
paine's technique
4
technique intraoperative
4
ventricular
4

Similar Publications

Unlabelled: Social cognition spans from perceiving agents and their interactions to making inferences based on theory of mind (ToM). Despite their frequent co-occurrence in real life, the commonality and distinction between social interaction perception and ToM at behavioral and neural levels remain unclear. Here, participants ( = 231) provided moment-by-moment ratings of four text and four audio narratives on social interactions and ToM engagement.

View Article and Find Full Text PDF

Unlabelled: The basal ganglia play a crucial role in action selection by facilitating desired movements and suppressing unwanted ones. The substantia nigra pars reticulata (SNr), a key output nucleus, facilitates movement through disinhibition of the superior colliculus (SC). However, its role in action suppression, particularly in primates, remains less clear.

View Article and Find Full Text PDF

Heterojunctions (HJs) based on two-dimensional (2D) transition metal dichalcogenides are considered promising candidates for next-generation electronic and optoelectronic devices. Here, vertical (V-type) and lateral (L-type) HJ diodes based on metallic 1T-VSe and semiconducting 2H-WSe with out-of-plane and in-plane contacts are designed. First-principles quantum transport simulations reveal that both V- and L-type VSe/WSe HJ diodes form p-type Schottky contacts.

View Article and Find Full Text PDF

Unlabelled: Chronic lateral ankle instability is a common diagnosis in foot and ankle clinics. Internal Brace (IB) augmentation is a surgical procedure that utilizes fibertape augmentation of the lateral ankle ligaments. Studies have shown the superiority of fibertape augmentation over traditional lateral ankle stabilization procedures such as the Brostrom or Brostrom-Gould.

View Article and Find Full Text PDF

Patient-specific flanged acetabular components are utilized to treat failed total hip arthroplasties with severe acetabular defects. We previously developed and published a finite element model that investigated the impact of hip joint center lateralization on construct biomechanics during gait conditions. This model consisted of a patient-specific implant designed to address a superior-medial defect created in a standard pelvic geometry.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!