AI Article Synopsis

  • The study aimed to measure pancreatic blood flow using advanced MR imaging techniques and to observe how this flow changes during secretin stimulation in ten healthy volunteers.
  • Results showed significant differences in blood flow across different regions of the pancreas, with a notable increase in perfusion after secretin administration, particularly in the tail region.
  • Overall, the research highlights the efficacy of dynamic contrast-enhanced MR imaging for noninvasive assessment of pancreatic perfusion, demonstrating increased variability during secretin stimulation.

Article Abstract

Purpose: To prospectively quantify pancreatic regional perfusion with dynamic contrast material-enhanced magnetic resonance (MR) imaging by using a one-compartment model and to assess perfusion changes during secretin stimulation in healthy volunteers.

Materials And Methods: The study had institutional review board approval, and written informed consent was obtained. Ten healthy volunteers (five men, five women; mean age, 24.7 years +/- 1.9 [standard deviation]; range, 22-29 years) underwent MR imaging pancreatic perfusion studies performed twice without secretin and twice during secretin stimulation. Dynamic contrast-enhanced MR imaging consisted of saturation-recovery T1-weighted turbo-field-echo imaging with peripheral pulse triggering and respiratory tracking. A dose of 0.05 mmol gadodiamide per kilogram of body weight was injected at a rate of 3.5 mL/sec. Regional perfusion parameters were fitted with a one-compartment model. The analysis of variance test for repeated measurements was used to assess differences in pancreatic perfusion without and that with secretin administration.

Results: Significant differences in perfusion parameters between the three pancreatic regions were observed (P < .05). During secretin stimulation, a significant difference was observed only between the body and the tail of the pancreas (P = .02). A significant increase (P = .003) in pancreatic perfusion was observed after secretin administration. Mean pancreatic perfusion was 184 mL/min/100 g of tissue +/- 71, 207 mL/min/100 g +/- 77, and 230 mL/min/100 g +/- 87 without secretin and 342 mL/min/100 g +/- 154, 338 mL/min/100 g +/- 156, and 373 mL/min/100 g +/- 176 after secretin stimulation in the head, body, and tail of the pancreas, respectively. Intraindividual variability was 21% without secretin stimulation and 46% with secretin stimulation.

Conclusion: Dynamic contrast-enhanced MR imaging enables noninvasive quantification of regional pancreatic perfusion in resting conditions and demonstrates the increase in pancreatic perfusion during secretin stimulation in healthy subjects.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiol.2471070685DOI Listing

Publication Analysis

Top Keywords

pancreatic perfusion
28
secretin stimulation
28
ml/min/100 +/-
20
dynamic contrast-enhanced
12
contrast-enhanced imaging
12
secretin
12
stimulation healthy
12
perfusion
10
pancreatic
9
regional perfusion
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!