Effect of medial arch-heel support in inserts on reducing ankle eversion: a biomechanics study.

J Orthop Surg Res

Department of Orthopaedics and Traumatology, Prince of Wales Hospital, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong, China.

Published: February 2008

Background: Excessive pronation (or eversion) at ankle joint in heel-toe running correlated with lower extremity overuse injuries. Orthotics and inserts are often prescribed to limit the pronation range to tackle the problem. Previous studies revealed that the effect is product-specific. This study investigated the effect of medial arch-heel support in inserts on reducing ankle eversion in standing, walking and running.

Methods: Thirteen pronators and 13 normal subjects participated in standing, walking and running trials in each of the following conditions: (1) barefoot, and shod condition with insert with (2) no, (3) low, (4) medium, and (5) high medial arch-heel support. Motions were captured and processed by an eight-camera motion capture system. Maximum ankle eversion was calculated by incorporating the raw coordinates of 15 anatomical positions to a self-compiled Matlab program with kinematics equations. Analysis of variance with repeated measures with post-hoc Tukey pairwise comparisons was performed on the data among the five walking conditions and the five running conditions separately.

Results: Results showed that the inserts with medial arch-heel support were effective in dynamics trials but not static trials. In walking, they successfully reduced the maximum eversion by 2.1 degrees in normal subjects and by 2.5-3.0 degrees in pronators. In running, the insert with low medial arch support significantly reduced maximum eversion angle by 3.6 and 3.1 degrees in normal subjects and pronators respectively.

Conclusion: Medial arch-heel support in inserts is effective in reducing ankle eversion in walking and running, but not in standing. In walking, there is a trend to bring the over-pronated feet of the pronators back to the normal eversion range. In running, it shows an effect to restore normal eversion range in 84% of the pronators.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2266906PMC
http://dx.doi.org/10.1186/1749-799X-3-7DOI Listing

Publication Analysis

Top Keywords

medial arch-heel
20
arch-heel support
20
ankle eversion
16
support inserts
12
reducing ankle
12
standing walking
12
normal subjects
12
eversion
9
inserts reducing
8
pronators normal
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!