A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Technical means for objectification of medical treatments in the area of the deep stabilisation spinal system. | LitMetric

Technical means for objectification of medical treatments in the area of the deep stabilisation spinal system.

Neuro Endocrinol Lett

University of Southern Bohemia, Faculty of Education, Department of Physical Education and Sports, Czech Republic.

Published: February 2008

Information regarding two versions of an instrument called a muscle dynamometer, which enables detailed information about muscle activity in the deep stabilisation spinal system (DSSS), presented in this article. The MD01 (muscle dynamometer ver. 01) is a simple electromechanical instrument that allows measurement of muscle activity in two areas of the lumbar spine region. Measurements on patients have confirmed the usefulness of quantifying the initial state of a patient before rehabilitation as well as monitoring rehabilitation treatment; the MD01 is a suitable device for obtaining these measurements. However, a new and improved version of the MD01, the MD02, has been developed. The MD02 allows measurements in four different body regions and now has a PC interface, which allows achieving of patient information and data export for use with statistical software.

Download full-text PDF

Source

Publication Analysis

Top Keywords

deep stabilisation
8
stabilisation spinal
8
spinal system
8
muscle dynamometer
8
muscle activity
8
technical objectification
4
objectification medical
4
medical treatments
4
treatments area
4
area deep
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!