AI Article Synopsis

  • Glenohumeral arthroplasty can benefit from a method to estimate normal glenoid version using a validated 3D model.
  • In a study involving 14 subjects with osteoarthritis, 3D reconstructions of scapulae were created from CT scans to analyze the differences in glenoid version between healthy and arthritic joints.
  • The findings showed that the 3D vault model accurately approximates normal glenoid version in arthritic cases, indicating its potential for aiding in surgical corrections.

Article Abstract

Glenohumeral arthroplasty can involve correcting pathologic glenoid tilt or version. Predicting the physiologic glenoid version for a particular individual can be difficult. We propose using a previously validated, 3-dimensional, glenoid vault model as a template to predict normal glenoid version. Computed tomography scans of both shoulders were obtained in 14 subjects with unilateral glenohumeral osteoarthritis. Custom-developed graphic software was used to create a 3-D reconstruction of each scapula. Within the software, the vault model was placed in a best-fit orientation into each glenoid vault independently by 3 observers who were blinded to the contralateral scapula. Measurement differences between the glenoid and vault model were analyzed by repeated-measures analysis of variance. Standard errors of measurement (SEM) were calculated. Interobserver and intraobserver reliabilities were assessed. The healthy glenoid version averaged -7.0 degrees (SEM, 0.7 degrees ; range, 0 degrees to -14 degrees ). The arthritic glenoid version averaged -15.6 degrees (SEM, 0.7 degrees ; range, 1 degrees to -33 degrees ; P < .0001). The version of the implanted vault model measured -7.1 degrees (SEM, 0.7 degrees ; range, -1 degrees to -15 degrees ) on the healthy side and -7.2 degrees (SEM, 0.7 degrees ; range -2 degrees to -11 degrees ) on the arthritic side. Measurements between observers were not significantly different (P = .98). Interobserver and intraobserver correlation coefficients were 0.79 (P < .001) and 0.80 (P < .001). In the arthritic glenoid, the vault model reproducibly closely approximated the version of the normal contralateral glenoid, -7.2 degrees vs -7.0 degrees (P = .99) and is a novel and accurate method of estimating the normal glenoid version. This technique may be valuable in correcting pathologic glenoid version due to arthritis.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jse.2007.09.006DOI Listing

Publication Analysis

Top Keywords

glenoid version
28
vault model
24
glenoid vault
20
degrees
18
degrees sem
16
sem degrees
16
degrees range
16
range degrees
16
glenoid
13
normal glenoid
12

Similar Publications

Article Synopsis
  • The optimal treatment for B2 glenoid morphology in young, active osteoarthritis patients is debated, with various options like hemiarthroplasty, total shoulder arthroplasty (TSA), and reverse TSA available, each having pros and cons.
  • Eccentric glenoid reaming can be effective but risks damaging the bone structure, potentially complicating future surgeries, while bone grafting, though beneficial for some, comes with high complication rates.
  • Reverse TSA offers a more stable alternative when correcting version and inclination proves difficult, as it adapts better to glenoid deformities and maintains functionality with reduced bone stock.
View Article and Find Full Text PDF

[Influence analysis of glenohumeral bone structure on anterior shoulder instability].

Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi

December 2024

Department of Orthopedics, Sports Medicine Center, West China Hospital, Sichuan University, Chengdu Sichuan, 610041, P. R. China.

Objective: To investigate the effect of glenohumeral bone structure on anterior shoulder instability by three-dimensional CT reconstruction.

Methods: The clinical data of 48 patients with unilateral anterior shoulder dislocation (instability group) and 46 patients without shoulder joint disease (control group) admitted between February 2012 and January 2024 were retrospectively analyzed. There was no significant difference in gender and side between the two groups ( >0.

View Article and Find Full Text PDF

» Suture button fixation has emerged as an effective surgical construct in arthroscopic and open Latarjet and anterior glenoid reconstruction with free autograft bone with high rates of bone block healing.» Biomechanical data suggest that screw and suture button mechanical fixation constructs provide similar load to failure and stability for the Latarjet procedure.» Preliminary bone healing models have identified that flexible fixation may exhibit a higher degree of bone callus maturation, whereas rigid fixation results in excessive callus hyperplasia» Mechanical tensioner use provides consistent tensioning of suture button constructs and improves bone-to-bone healing rates when used for anterior glenoid reconstruction surgery.

View Article and Find Full Text PDF

Reverse Shoulder Arthroplasty Implant Design and Configuration has a Significant Effect on Conjoint Tendon Impingement.

J Shoulder Elbow Surg

December 2024

Roth | McFarlane Hand and Upper Limb Centre, St Joseph's Health Care, London, Canada; Department of Surgery, Western University, London, Canada. Electronic address:

Background: Anterior shoulder pain after reverse shoulder arthroplasty (RSA) is not uncommon and may be due to humeral impingement against the conjoint tendon during internal rotation (IR). It is unknown what effect different implant designs and configurations have on conjoint tendon impingement. The purpose of this study was to investigate the influence of several RSA implant design parameters on conjoint tendon impingement during IR.

View Article and Find Full Text PDF

Background: The role of anatomic factors in rotator cuff (RC) pathology or in the development of shoulder osteoarthritis (OA) is not yet well understood or recognized. While two-dimensional imaging and measurements are easy to capture and interpret, three-dimensional (3D) methods provide a more thorough description and analysis of the scapula's complex shape. The purpose of this study is to investigate whether scapular anatomy is associated with RC tears or glenohumeral OA using 3D statistical shape modelling (SSM).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!