A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Di(2-ethylhexyl)phosphoric acid-coconut oil supported liquid membrane for the separation of copper ions from copper plating wastewater. | LitMetric

Permeation of Cu(II) from its aqueous solution through a supported liquid membrane (SLM) containing di(2-ethylhexyl)phosphoric acid (D2EHPA) carrier dissolved in coconut oil has been studied. The effects of Cu(II), pH (in feed), H2SO4 (stripping) and D2EHPA (in membrane) concentrations have been investigated. The stability of the D2EHPA-coconut oil has also been evaluated. High Cu(II) concentration in the feed leads to an increase in flux from 4.1 x 10(-9) to 8.9 x 10(-9) mol/(m2 x s) within the Cu(II) concentration range 7.8 x 10(-4)-78.6 x 10(-4) mol/L at pH of 4.0 in the feed and 12.4 x 10-4 mol/L D2EHPA in the membrane phase. Increase in H2SO4 concentration in strip solution leads to an increase in copper ions flux up to 0.25 mol/L H2SO4, providing a maximum flux of 7.4 x 10(-9) mol/(m2 x s). The optimum conditions for Cu(II) transport are, pH of feed 4.0, 0.25 mol/L H2SO4 in strip phase and 12.4 x 10(-4) mol/L D2EHPA (membrane) in 0.5 microm pore size polytetrafluoroethylene (PTFE) membrane. It has been observed that Cu(II) flux across the membrane tends to increase with the concentration of copper ions. Application of the method developed to copper plating bath rinse solutions has been found to be successful in the recovery of Cu(II).

Download full-text PDF

Source
http://dx.doi.org/10.1016/s1001-0742(07)60236-8DOI Listing

Publication Analysis

Top Keywords

copper ions
12
d2ehpa membrane
12
10-4 mol/l
12
supported liquid
8
liquid membrane
8
copper plating
8
cuii concentration
8
leads increase
8
flux 10-9
8
10-9 mol/m2
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!