A new ischemic model using a radiofrequency wire electrode in a rabbit hindlimb.

Cardiovasc Intervent Radiol

Department of Radiology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, 224-1 Heukseok-dong, Dongjak-gu, Seoul, 156-755, South Korea.

Published: November 2008

The purpose of this study was to establish an ischemic rabbit hindlimb model using a radiofrequency (RF) wire electrode. We inserted a polytetrafluoroethylene-coated wire with a 2-cm exposed tip into the left superficial femoral artery of seven New Zealand white rabbits and performed RF ablation (RFA) while pulling the wire back. We assessed the clinical findings, angiography, computed tomography perfusion, and permeability surface until 6 weeks after RFA. The angiography demonstrated complete obstruction from the proximal external iliac artery to the distal superficial femoral artery and showed a gradual increment in the angiogenic score, which represents the degree of angiogenesis (r = 0.86, p < 0.0001). The left-to-right ratios of the computed tomography perfusion and permeability surface were significantly reduced after 4 days (p < 0.05), and then they gradually increased with time. We conclude that endovascular RFA using an RF wire electrode is a reproducible and measurable way to create an ischemic rabbit hindlimb model.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00270-008-9302-zDOI Listing

Publication Analysis

Top Keywords

wire electrode
12
rabbit hindlimb
12
model radiofrequency
8
radiofrequency wire
8
ischemic rabbit
8
hindlimb model
8
superficial femoral
8
femoral artery
8
computed tomography
8
tomography perfusion
8

Similar Publications

The purpose was to assess whether visual feedback of torque contributes to motor unit (MU) firing rate reduction observed during post-activation potentiation (PAP) of skeletal muscle. From 15 participants 23 MUs were recorded with intramuscular fine-wire electrodes from the tibialis anterior during isometric dorsiflexion contractions at 20% of maximum, with and without both PAP and visual feedback of torque. A 5s maximal voluntary contraction (MVC) was used to induce PAP, and evoked twitch responses were assessed before and after.

View Article and Find Full Text PDF

Flexible disk ultramicroelectrode: Facile preparation and high-resolution scanning electrochemical microscopy imaging.

Anal Chim Acta

January 2025

State Key Laboratory of Electroanalytical Chemistry, Jilin Province Key Laboratory of Low Carbon Chemical Power, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, 130022, Jilin, China; School of Applied Chemistry and Engineering, University of Science and Technology of China, Hefei, 230026, Anhui, China. Electronic address:

Background: Scanning electrochemical microscopy (SECM) is a kind of scanning probe technology that enables the obtainment of surface morphology and electrochemical information by recording changes in Faraday current triggered by the movement of probe.

Results: In this work, flexible disk ultramicroelectrode (UME) with highly repeatable geometry are fabricated through a simple and universal strategy that involves vacuum pulling the glass capillaries inserted with platinum wire (gold wire, carbon fiber, etc.), followed by a rapidly heated sealing and polishing process.

View Article and Find Full Text PDF

Wire arc additive manufacturing (WAAM) with a special arc mode of cold metal transfer pulse advanced (CMT-PADV) is an ideal additive manufacturing process for fabricating aerospace components, primarily high-strength aluminum alloys, offering advantages such as high deposition rates and low cost. However, the numerical simulation of the CMT-PADV WAAM process has not been researched until now. In this study, we first developed a three-dimensional fluid dynamics model for the CMT-PADV WAAM of 7075 aluminum alloy, aiming at analyzing the droplet transition and molten pool flow.

View Article and Find Full Text PDF

Assessment of Surface Integrity in Precision Electrical Discharge Machining of HSS EN HS6-5-2C.

Micromachines (Basel)

December 2024

Department of Process Engineering, Faculty of Manufacturing Technologies with the Seat in Presov, Technical University of Kosice, Sturova 31, 080 01 Presov, Slovakia.

The integrity of the machined surface in precision wire electrical discharge machining (WEDM) of electrically conductive materials is one of the most important quality indicators. The integrity parameters of the machined surface are primarily monitored in terms of micro and macro geometry parameters. This paper presents the results obtained as a part of experimental research aimed at evaluating surface crack density (SCD) when machining EN HS6-5-2C using WEDM technology.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!