Background And Aims: At present, revision surgery of a total hip replacement is a major problem that must be dealt with by all orthopedic facilities. Aseptic loosening of the acetabular component is often associated with destruction of the original spherical shape of the acetabulum and the formation of bone defects. An orthopedist faces the challenge of acetabular revision and stable fixation of the new acetabular component in an effort to re-establish the functioning of the hip replacement.
Material And Methods: The authors evaluated a group of 74 patients in whom they implanted an oblong revision cup due to aseptic loosening of the acetabular component from August 2000 until December 2003. The mean duration of the follow-up period was 63 months (ranging from 38 to 78 months).
Results And Conclusions: The authors reported very good results from the use of this implant, where osteointegration and good functional outcome evaluated according to the Harris Hip Score (HHS) were achieved in 95% of cases. The long-term outcome should be the subject of further investigation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/145749690709600411 | DOI Listing |
Front Artif Intell
December 2024
Department of Orthopedic Hip and Knee Surgery, Rasoul-e-Akram Hospital, Iran University of Medical Sciences, Tehran, Iran.
Background: Total Hip Arthroplasty (THA) is a transformative surgical intervention for hip joint disorders, necessitating meticulous preoperative planning for optimal outcomes. With the emergence of Artificial Intelligence (AI), preoperative planning paradigms have evolved, leveraging AI algorithms for enhanced decision support and imaging analysis. This systematic review aims to comprehensively evaluate the role of AI in THA preoperative planning, synthesizing evidence from studies exploring various AI techniques and their applications.
View Article and Find Full Text PDFHip Int
January 2025
Department of Orthopaedic Surgery, Hospital de Sant Pau (HSCSP), Barcelona, Spain.
Background: Survival at 25 years' follow-up for total hip arthroplasty (THA) has been reported at 5%-77%, with hydroxyapatite (HA) coating, due to its osteo-conductive properties, used to enhance implant fixation and survival. The progressive increase in life expectancy raises doubts regarding HA-coated THA survival and THA revision surgery risk. The aim of our study was to retrospectively analyse survival for primary uncemented fully HA-coated THA after 28 years' follow-up.
View Article and Find Full Text PDFJ Orthop Res
January 2025
Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, New York, USA.
Patient-specific flanged acetabular components are utilized to treat failed total hip arthroplasties with severe acetabular defects. We previously developed and published a finite element model that investigated the impact of hip joint center lateralization on construct biomechanics during gait conditions. This model consisted of a patient-specific implant designed to address a superior-medial defect created in a standard pelvic geometry.
View Article and Find Full Text PDFArthroplasty
January 2025
Sant'Andrea Hospital, Faculty of Medicine and Psychology, Sapienza University of Rome, 00162, Rome, Italy.
Background: Proper positioning of a total hip arthroplasty (THA) plays a crucial role in the success and long-term survivorship of the implant. Cup positioning within the Lewinnek Safe Zone (LSZ) does not, however, avoid implant dislocation. Thus, the concept of a functional cup position has been introduced.
View Article and Find Full Text PDFWorld J Orthop
December 2024
Department for Science, Dubai College, Dubai 00000, Dubayy, United Arab Emirates.
Hip arthroplasty in patients with a history of paediatric hip disorders presents a significant challenge for orthopaedic surgeons. These patients are typically younger and have greater functional demands. Therefore, achieving optimal biomechanical conditions is crucial, involving placement of the acetabulum at the ideal centre of rotation and securing a stable femoral component with good offset to preserve abductor muscle function and restore leg length.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!