Purpose: To evaluate the influence of the brush type as a carrier of priming adhesive solutions and the use of paper points as a remover of the excess of these solutions on the push-out bond strength of resin cement to bovine root dentin. The null hypotheses were that brush type and the use of paper points do not affect the bond strength.

Materials And Methods: The canals of 80 single-root bovine roots (16 mm in length) were prepared at 12 mm using the preparation drill (FRC Postec Plus, Ivoclar). Half of each root was embedded in acrylic resin and the specimens were divided into 8 groups, considering the factors "brush type" (4 levels) and "paper point" (2 levels) (n = 10): Gr 1: small microbrush (Cavi-Tip, SDI); Gr 2: Microbrush (Dentsply); Gr 3: Endobrush (Bisco); Gr 4: conventional brush (Bisco); Gr 5: Cavi-Tip (SDI) + paper points; Gr 6: Microbrush (Dentsply) + paper points; Gr 7: Endobrush (Bisco) + paper points; Gr 8: conventional brush (Bisco) + paper points. The root dentin was treated with a multistep total-etch adhesive system (All Bond 2). The adhesive system was applied using each microbrush, with and without using paper points. One fiber post was molded with addition silicon and 80 posts were made of resin cement (Duolink). The resin posts were luted (Duolink resin cement), and the specimens were stored for 24 h in water at 37 degrees C. Each specimen was cut into 4 disk-shaped samples (1.8 mm in thickness), which were submitted to the push-out test.

Results: The brush type (p < 0.0001) (small microbrush > microbrush = endobrush = conventional brush) and the use of paper points (p = 0.0001) (with > without) influenced the bond strength significantly (two-way ANOVA). The null hypotheses were rejected.

Conclusion: The smallest brush (Cavi-Tip) and the use of paper points significantly improved the resin bond to bovine root dentin.

Download full-text PDF

Source

Publication Analysis

Top Keywords

paper points
40
brush type
16
root dentin
16
resin cement
12
conventional brush
12
paper
10
points
10
influence brush
8
type carrier
8
adhesive solutions
8

Similar Publications

Two-point contact is one of the fundamental problems of wheel-rail contact in switch area. The contact state and the distribution of forces are complex and essential points in wheel-rail relationship. Given the problem that the current dynamic wheel-rail contact state is challenging to detect, a theory to detect the two-point contact state of the wheel-rail in switch area using a discrete gauge column was presented and proved in the finite element model.

View Article and Find Full Text PDF

Periapical bone edema volume in 3D MRI is positively correlated with bone architecture changes.

Insights Imaging

January 2025

Diagnostic and Interventional Radiology, University Hospital of Zurich, University Zurich, Zurich, Switzerland.

Objectives: To compare and correlate bone edema volume detected by 3D-short-tau-inversion-recovery (STIR) sequence to osseous decay detected by a T1-based sequence and conventional panoramic radiography (OPT).

Materials And Methods: Patients with clinical evidence of apical periodontitis were included retrospectively and received OPT as well as MRI of the viscerocranium including a 3D-STIR and a 3D-T1 gradient echo sequence. Bone edema was visualized using the 3D-STIR sequence and periapical hard tissue changes were evaluated using the 3D-T1 sequence.

View Article and Find Full Text PDF

Carcinoembryonic antigen (CEA) and C-reactive protein (CRP) are biomacromolecules known as cancer and inflammatory markers. Thus, they play a crucial role in early cancer diagnosis, post-treatment recurrence detection, and tumor risk assessment. This paper describes the development of an ultrasensitive and selective imprinted paper-based analytical device (PAD) as impedance sensor for determination of CEA and CRP in serum samples for point-of-care testing (POCT).

View Article and Find Full Text PDF

Chest imaging in children presents unique challenges due to varying requirements across age groups. For chest radiographs, achieving optimal images often involves careful positioning and immobilisation techniques. Antero-posterior projections are easier to obtain in younger children, while lateral decubitus radiographs are sometimes used when expiratory images are difficult to obtain and for free air exclusion.

View Article and Find Full Text PDF

Objectives: This study aimed to develop a multimodal radiopathomics model utilising preoperative ultrasound (US) and fine-needle aspiration cytology (FNAC) to predict large-number cervical lymph node metastasis (CLNM) in patients with clinically lymph node-negative (cN0) papillary thyroid carcinoma (PTC).

Materials And Methods: This multicentre retrospective study included patients with PTC between October 2017 and June 2024 across seven institutions. Patients were categorised based on the presence or absence of large-number CLNM in training, validation, and external testing cohorts.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!