Objective: The aim was to compare 2-year outcomes with the routine use of drug-eluting stents (DES) (>75% "off-label") with a comparable group treated with bare-metal stents (BMS).
Background: Safety concerns >1 year from implantation have been raised about DES used "off-label." There are limited data comparing DES and BMS in "off-label" patients.
Methods: Clinical outcomes (nonfatal myocardial infarction [MI], all-cause mortality) were assessed in 1,164 consecutive patients who received BMS in the year before introduction of DES at Wake Forest University Baptist Medical Center and 1,285 consecutive patients who received DES after it became our routine choice. "On-label" stent use was defined as treatment for a single de novo lesion <30 mm, without recent MI or other major illnesses.
Results: At 2 years, the hazard ratio for DES compared with BMS for nonfatal MI or death was 0.77 (95% confidence interval [CI] 0.62 to 0.95), for all-cause mortality 0.71 (0.54 to 0.92), and stent thrombosis (ST) 0.97 (0.49 to 1.91). "On-label" stent procedures were associated with lower risk of MI, death, and ST than "off-label" stent procedures. For "off-label" stent procedures, the hazard ratio for DES compared with BMS for nonfatal MI or death was 0.78 (95% CI 0.62 to 0.98), all-cause mortality 0.72 (0.54 to 0.94), and ST 0.91 (0.46 to 1.80). The hazard of nonfatal MI or death was similar or lower for DES than BMS in high-risk subgroups, including renal failure and recent MI.
Conclusions: The routine clinical use of drug-eluting stents for "off-label" indications was associated with lower nonfatal MI and death at 2 years than in a comparable group of patients treated with BMS.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jacc.2007.08.064 | DOI Listing |
Introduction: In 2015, Society for Vascular Surgery guidelines on claudication management were released spanning optimal medical management, procedural, and post-procedure recommendations. Uptake of guidelines and changes to clinical practice over time remain unknown. This study hypothesized that guideline aligned practice increased after guideline release.
View Article and Find Full Text PDFJ Endovasc Ther
January 2025
Vascular Unit, Department of Surgery, Mater Dei Hospital, Msida, Malta.
Purpose: The use of surgeon-modified fenestrated endograft to treat a bleeding complication in the common iliac artery.
Technique: An Endurant limb graft was modified on back table in theater after planning the fenestration using a semi-automated centerline. The Endurant stent was planned to land flush at the aortic bifurcation.
Materials (Basel)
December 2024
Fraunhofer Institute for Ceramic Technologies and Systems IKTS, Maria-Reiche-Strasse 2, 01109 Dresden, Germany.
Coated metallic stents are the next generation of metallic stents with improved surface properties. To evaluate the degradation behavior of stents in vitro, different in vitro degradation models can be applied: (i) static immersion test: degradation under static fluid condition, (ii) fluid dynamic test: degradation under flowing fluid, and (iii) electrochemical corrosion test: degradation under the influence of electric potential. During these experimental procedures, stents interact with the simulated blood plasma, and degradation products are formed in the form of depositions on the stent surface, likewise in vivo experiments.
View Article and Find Full Text PDFAnn Thorac Surg Short Rep
December 2024
Division of Cardiac Surgery, Inova Heart and Vascular Institute, Inova Health Systems, Falls Church, Virginia.
Background: DeBakey type I aortic dissections (AD) are most frequently treated with hemiarch repair. A subset of patients demonstrates persistent distal end-organ ischemia secondary to persistent true lumen (TL) compression. We describe the use of bare metal stent grafting across the residual arch dissection with the Zenith Dissection Endovascular Stent (ZDES, Cook Medical) in 7 patients with type I AD that was repaired in a hemiarch configuration with a compromised distal TL and organ malperfusion.
View Article and Find Full Text PDFInt J Mol Sci
December 2024
Pre-Clinical Research Centre, Wrocław Medical University, Marcinkowskiego 1, 50-368 Wrocław, Poland.
Percutaneous Coronary Intervention (PCI) is a treatment method that involves reopening narrowed arteries with a balloon catheter that delivers a cylindrical, mesh-shaped implant device to the site of the stenosis. Currently, by applying a coating to a bare metal stent (BMS) surface to improve biocompatibility, the main risks after PCI, such as restenosis and thrombosis, are reduced while maintaining the basic requirements for the mechanical behavior of the stent itself. In this work, for the first time, the development and optimization process of the spatial structure of the Co-Cr stent (L-605) with a graphene-based coating using cold-wall chemical vapor deposition (CW-CVD) to ensure uniform coverage of the implant was attempted.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!