Background And Purpose: In this study, a new method is introduced, which allows the overlay of three-dimensional structures, that have been delineated on transverse slices, onto the fluoroscopy from conventional simulators in real time.
Patients And Methods: Setup deviations between volumetric imaging and simulation were visualized, measured and corrected for 701 patient isocenters.
Results: Comparing the accuracy to mere virtual simulation lacking additional X-ray imaging, a clear benefit of the new method could be shown. On average, virtual prostate simulations had to be corrected by 0.48 cm (standard deviation [SD] 0.38), and those of the breast by 0.67 cm (SD 0.66).
Conclusion: The presented method provides an easy way to determine entity-specific safety margins related to patient setup errors upon registration of bony anatomy (prostate 0.9 cm for 90% of cases, breast 1.3 cm). The important role of planar X-ray imaging was clearly demonstrated. The innovation can also be applied to adaptive image-guided radiotherapy (IGRT) protocols.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00066-008-1742-5 | DOI Listing |
Adv Sci (Weinh)
January 2025
Institute for Electrochemical Energy Storage (CE-IEES), Helmholtz-Zentrum Berlin für Materialien und Energie, Hahn-Meitner-Platz 1, 14109, Berlin, Germany.
Sn-based electrodes are promising candidates for next-generation lithium-ion batteries. However, it suffers from deleterious micro-structural deformation as it undergoes drastic volume changes upon lithium insertion and extraction. Progress in designing these materials is limited to complex structures.
View Article and Find Full Text PDFPLoS One
January 2025
Department of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan.
Objective: This study aimed to introduce and evaluate a novel software-based system, BioTrace, designed for real-time monitoring of thermal ablation tissue damage during image-guided radiofrequency ablation for hepatocellular carcinoma (HCC).
Methods: BioTrace utilizes a proprietary algorithm to analyze the temporo-spatial behavior of thermal gas bubble activity during ablation, as seen in conventional B-mode ultrasound imaging. Its predictive accuracy was assessed by comparing the ablation zones it predicted with those annotated by radiologists using contrast-enhanced computed tomography (CECT) 24 hours post-treatment, considered the gold standard.
Oper Neurosurg (Hagerstown)
February 2025
Rhoton Neurosurgery and Otolaryngology Surgical Anatomy Program, Mayo Clinic, Rochester , Minnesota , USA.
Background And Objectives: The coexistence of complete carotico-clinoid bridge (CCB), an ossification between the anterior (ACP) and the middle clinoid (MCP), and an interclinoidal osseous bridge (ICB), between the ACP and the posterior clinoid (PCP), represents an uncommonly reported anatomic variant. If not adequately recognized, osseous bridges may complicate open or endoscopic surgery, along with the pneumatization of the ACP, especially when performing anterior or middle clinoidectomies.
Methods: According to Preferred Reporting Items for Systematic Reviews and Meta-Analyses for Scoping Reviews guidelines, a systematic scoping review was conducted up to June 5, 2023.
Clin Implant Dent Relat Res
February 2025
State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, Wuhan, China.
Objectives: To compare the clinical effectiveness of a novel bioceramic (BC) with a control xenograft (BO) for guided bone regeneration (GBR) performed simultaneously with implant placement.
Materials And Methods: This clinical study enrolled patients with insufficient bone volume who required GBR during implant placement to increase bone width using either BC or BO. Outcome measures included a dimensional reduction in buccal bone thickness measured by cone beam computed tomography performed immediately post-surgery and at 6 months postoperatively (ΔHBBT), soft tissue healing at 14 days, 1 month, and 6 months postoperatively, and complications rates.
Radiol Bras
January 2025
Universidade Federal de Juiz de Fora (UFJF), Juiz de Fora, MG, Brazil.
Sclerosing bone dysplasias encompass abnormalities in bone density, divided into hereditary and nonhereditary forms. Primarily diagnosed through radiography, they are often incidental findings. Among the hereditary forms, the following stand out: osteopetrosis, osteopoikilosis, multiple diaphyseal sclerosis (ribbing disease), osteopathia striata, and Camurati-Engelmann disease.