This study examined the importance of aortic dimensions in determining pulse pressure in elderly hypertensives participating in the 2nd Australian National Blood Pressure Study, including a substantial number not previously receiving blood pressure lowering medication. Aortic dimensions were determined by ultrasound at the transverse arch and at the insertion of the aortic valve. Unadjusted data showed negative (P<0.001) correlations between central (carotid) and (brachial) peripheral pulse pressure and both arch (-0.200, -0.181) and outflow tract (-0.238, -0.238) diameters. Correlations were similar in those previously treated with blood pressure lowering medication and in the treatment naïve. Central pulse pressure (84+/-26 versus 75+/-28 mm Hg, P<0.001) was higher and aortic dimensions (transverse arch 2.56+/-0.31 versus 2.88+/-0.35 mm, P<0.001) smaller in women than men. Women had greater aortic stiffness (beta index 29.4+/-36.1 versus 22.1+/-21.3, P<0.03). Other bivariate correlates of central pulse pressure were age, mean arterial pressure, height, heart rate, augmentation index, aortic stiffness (all P<0.001), and weight (P=0.027). In multivariate analyses gender remained a predictor of central pulse pressure (P<0.001) even with inclusion of aortic dimensions (P=0.013) height and weight. Other significant terms were age, heart rate, mean blood pressure, and aortic stiffness (all P<0.001). These findings demonstrate an independent inverse relation between aortic size and pulse pressure in older hypertensive subjects. Differences in aortic dimensions and stiffness between genders do not fully account for the observed blood pressure differences, suggesting that a contributory factor to gender differences in pulse pressure is an increased age-related mismatch in ventricular function and aortic stiffness in women compared with men.

Download full-text PDF

Source
http://dx.doi.org/10.1161/HYPERTENSIONAHA.107.106310DOI Listing

Publication Analysis

Top Keywords

aortic dimensions
12
pulse pressure
8
pressure elderly
8
blood pressure
8
smaller aortic
4
dimensions fully
4
fully account
4
account greater
4
greater pulse
4
pressure
4

Similar Publications

Introduction: Determining the normal diameter of the abdominal aorta in different populations and its relationship with other demographic factors is crucial for diagnosing and managing abdominal aortic diseases. This study aimed to assess the size of the abdominal aorta in a healthy Iranian population.

Methods: This cross-sectional study included healthy individuals.

View Article and Find Full Text PDF

Background: There are several high-risk treatment options for valve failure of a biological full root replacement. When tailoring the best treatment option for the patient, implantation of a rapid deployment valve (RDV) should be considered.

Case Presentation: Six patients presented with aortic regurgitation in a full root Freestyle bioprosthesis.

View Article and Find Full Text PDF

Background: Accurate assessment of aortic root is crucial for the preprocedural planning of transcatheter aortic valve replacement (TAVR). A variety software is emerging for the semiautomated or automated measurements during TAVR planning. This study evaluated a new deep-learning (DL) tool based on cardiac computed tomography angiography (CCTA) for fully automatic assessment of aortic root.

View Article and Find Full Text PDF

Objectives: The Ross procedure is currently receiving renewed interest. Its function and durability depend on preservation of pulmonary valve anatomy; limited data exist on normal pulmonary valve geometry. The objective was to compare aortic and pulmonary root and cusp dimensions in adults with normal tricuspid aortic and pulmonary valves.

View Article and Find Full Text PDF

Introduction: The template method (TM), pioneered by Ozaki for aortic valve neocuspidization (AVNeo), has been widely adopted for aortic valve replacement, though it requires specialized instruments. This study introduces a novel formula method (FM), which uses the diameter of the aortic valve fibrous ring (AV-D) to determine the dimensions of the neocusps to be trimmed from autologous without the need for templates, potentially reducing costs and complexity. We aimed to compare the clinical outcomes of the FM with the established TM in patients undergoing AVNeo.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!