Purpose: Respiration-induced organ motion is a major source of positional, or geometric, uncertainty in thoracic radiotherapy. Interventions to mitigate the impact of motion include audio-coached respiration-gated radiotherapy (RGRT). To assess the impact of coaching on average tumor position during gating, we analyzed four-dimensional computed tomography (4DCT) scans performed both with and without audio-coaching.

Methods And Materials: Our RGRT protocol requires that an audio-coached 4DCT scan is performed when the initial free-breathing 4DCT indicates a potential benefit with gating. We retrospectively analyzed 22 such paired scans in patients with well-circumscribed tumors. Changes in lung volume and position of internal target volumes (ITV) generated in three consecutive respiratory phases at both end-inspiration and end-expiration were analyzed.

Results: Audio-coaching increased end-inspiration lung volumes by a mean of 10.2% (range, -13% to +43%) when compared with free breathing (p = 0.001). The mean three-dimensional displacement of the center of ITV was 3.6 mm (SD, 2.5; range, 0.3-9.6mm), mainly caused by displacement in the craniocaudal direction. Displacement of ITV caused by coaching was more than 5 mm in 5 patients, all of whom were in the subgroup of 9 patients showing total tumor motion of 10 mm or more during both coached and uncoached breathing. Comparable ITV displacements were observed at end-expiration phases of the 4DCT.

Conclusions: Differences in ITV position exceeding 5 mm between coached and uncoached 4DCT scans were detected in up to 56% of mobile tumors. Both end-inspiration and end-expiration RGRT were susceptible to displacements. This indicates that the method of audio-coaching should remain unchanged throughout the course of treatment.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijrobp.2007.11.061DOI Listing

Publication Analysis

Top Keywords

4dct scans
8
end-inspiration end-expiration
8
coached uncoached
8
itv
5
impact audio-coaching
4
position
4
audio-coaching position
4
position lung
4
lung tumors
4
tumors purpose
4

Similar Publications

Respiratory motion phantoms can be used for evaluation of CT imaging technologies such as motion artifact reduction algorithms and deformable image registration. However, current respiratory motion phantoms do not exhibit detailed lung tissue structures and thus do not provide a realistic testing environment. This paper presents PixelPrint, a method for 3D-printing deformable lung phantoms featuring highly realistic internal structures, suitable for a broad range of CT evaluations, optimizations, and research.

View Article and Find Full Text PDF

Purpose: Pulmonary perfusion imaging is a key lung health indicator with clinical utility as a diagnostic and treatment planning tool. However, current nuclear medicine modalities face challenges like low spatial resolution and long acquisition times which limit clinical utility to non-emergency settings and often placing extra financial burden on the patient. This study introduces a novel deep learning approach to predict perfusion imaging from non-contrast inhale and exhale computed tomography scans (IE-CT).

View Article and Find Full Text PDF

Objective: The aim of the study is to assess the diagnostic accuracy of 4-dimensional computed tomography (4D-CT) scans for patients with primary hyperparathyroidism (pHPT) after negative or inconclusive Technetium-99m sestamibi single-photon emission computed tomography scan.

Methods: A literature search of several databases was conducted from inception to August 2023. Eligible studies reported adult patients (>18 years old) who underwent 4D-CT after negative or inconclusive sestamibi results.

View Article and Find Full Text PDF

Localization in primary hyperparathyroidism.

Best Pract Res Clin Endocrinol Metab

December 2024

Department of Nuclear Medicine, Post Graduate Institute of Medical Education and Research, Sector 12, Chandigarh 160012, India. Electronic address:

Primary hyperparathyroidism is the main cause of hypercalcemia, resulting predominantly from parathyroid adenomas followed by hyperplasia. Diagnosis relies on clinical and biochemical parameters. Accurate pre-operative localization is mandatory for better surgical outcome.

View Article and Find Full Text PDF

Background: Surgery is the preferred treatment for primary hyperparathyroidism. Minimally invasive parathyroidectomy is only feasible with accurate preoperative localisation. Virtual 3D anatomical models can be constructed from patient-specific CT scans using segmentation software.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!