[Application of spindle-view in the enucleation porcine of oocytes].

Sheng Wu Gong Cheng Xue Bao

Animal Husbandry and Veterinary Research Institute, Shanghai Academy of Agricultural Sciences, Shanghai 201106, China.

Published: November 2007

The Spindle-view, a specialized instrument for observing spindle image, was applied to observe the meiotic spindles of vitro matured porcine oocytes at 36, 42, 44, 48h, and enucleation from porcine, comparing to the previously methods (McGrath-Solter's method and two-step-squeezing method) in the enucleated. The results showed that: (1) there was no noticeable differences at vicinity of spindle images and 1st polar body among in vitro matured porcine oocytes at 40-48 h under the instrument; (2) Spindle-view is suitable for the observation of meiotic spindles of matured oocytes and enucleation from porcine; the modified Spindle-view method for enucleation is significantly better than McGrath-Solter' s method and two-step-squeezing method in the enucleated rates (95.5%, 42.1%, 74.2%, P < 0.0l) of absolutely removing nuclei matter; (3) the spindle images could be used to monitor the oocyte qualities.

Download full-text PDF

Source

Publication Analysis

Top Keywords

enucleation porcine
12
meiotic spindles
8
vitro matured
8
matured porcine
8
porcine oocytes
8
method two-step-squeezing
8
two-step-squeezing method
8
method enucleated
8
spindle images
8
porcine
5

Similar Publications

Purpose: Autologous retinal transplantation has been successfully employed in the treatment of large and myopic macular holes that are refractory to standard surgical treatments. Patients transplanted with a peripheral neurosensory retinal graft have shown unexpected improvements in visual acuity. The study aims to investigate if neural integration of the graft takes place in a porcine model of retinal hole.

View Article and Find Full Text PDF

Intravitreal chlorhexidine for sterilizing the vitreous cavity in an animal model of bacterial endophthalmitis.

Cutan Ocul Toxicol

December 2024

Edward Harkness Institute of Ophthalmology, Vagelos College of Physicians and Surgeons, Columbia University Medical Center, New York, USA.

Article Synopsis
  • The study assesses how effective and safe intravitreal chlorhexidine (CHX) is in sterilizing the vitreous cavity for bacterial endophthalmitis.
  • In vitro, CHX concentrations above 6.25 µg/mL effectively killed bacteria, and doses below 200 µg/mL did not harm retinal cells.
  • Animal testing showed that CHX concentrations of 20-100 µg/mL could sterilize the vitreous without causing harmful effects, suggesting potential for clinical application.*
View Article and Find Full Text PDF

Purpose: To investigate the histopathological changes following subretinal amniotic membrane transplantation in an in vivo porcine model of retinal holes.

Methods: Left eyes of 12 Danish Landrace pigs were vitrectomized under full anesthesia. A subretinal bleb was created before excising a retinal hole (1154-2934 µm) using a 23-gauge vitrector.

View Article and Find Full Text PDF

Persistent excessive inflammation caused by neutrophil and macrophage dysfunction in the wound bed leads to refractory response during wound healing. However, previous studies using cytokines or drugs often suffer from short half-lives and limited targeting, resulting in unsatisfactory therapeutic effects. Herein, the enucleated mesenchymal stem cell is engineered by aptamer bioorthogonal chemistry to modify the cell membrane and mRNA loading in the cell cytoplasm as a novel delivery vector (Cargocyte) with accurate targeting and sustained cytokine secretion.

View Article and Find Full Text PDF

An approximately 26-year-old, suspected female, red-tailed hawk (Buteo jamaicensis) was presented with a history of chronic ocular changes of the left eye likely secondary to blunt trauma resulting in blindness and phthisis bulbi. Ophthalmic evaluation of OS revealed a large intraocular mass, 3+ aqueous flare indicating anterior uveitis, and severely decreased intraocular pressure measuring 5 mmHg. Ocular ultrasound revealed an abnormal, spherical shaped and hyperechoic lens, as well as hyperechoic material or a mass lesion in the posterior segment.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!