Studies on circular isocentric cone-beam trajectories for 3D image reconstructions using FDK algorithm.

Comput Med Imaging Graph

Department of Medical Physics, School of Medicine, University of Patras, Patras 26500, Greece.

Published: April 2008

Image reconstruction from X-ray cone-beam projections collected along a single-circular source trajectory is commonly done using the Feldkamp (FDK) algorithm which performs well only with a small cone-angle. Although this method does not provide an "exact" reconstruction, the approximation is considered adequate for many purposes. In FDK reconstruction the degree of inaccuracy is highly object-dependent, and the largest errors are to be expected for planes parallel to and remote from the midplane. In this study we investigated the possibility to accurately reconstruct these regions by applying FDK algorithm along three-orthogonal to each other circular scanning trajectories. After appropriate weighting, based on the expected errors for each individual reconstruction, the final 3D volume contains the most precisely recovered values. By comparing the quality of 3D reconstructed images using FDK algorithm on projections acquired along classical single-circular and two- and three-orthogonal circular trajectories, we show that using three-orthogonal circular isocentric orbits with an error-based weighted averaging, image quality of reconstructed slices significantly improves, reconstruction error due to circular scanning is reduced and becomes almost independent of the slice position even for relatively large cone-angles.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.compmedimag.2007.12.005DOI Listing

Publication Analysis

Top Keywords

fdk algorithm
16
three-orthogonal circular
12
circular isocentric
8
circular scanning
8
quality reconstructed
8
fdk
5
reconstruction
5
studies circular
4
isocentric cone-beam
4
cone-beam trajectories
4

Similar Publications

Evaluation of charge summing correction in CdTe-based photon-counting detectors for breast CT: performance metrics and image quality.

J Med Imaging (Bellingham)

January 2025

U.S. Food and Drug Administration, Office of Science and Engineering Labs, Division of Imaging, Diagnostics, and Software Reliability, Silver Spring, Maryland, United States.

Purpose: We evaluate the impact of charge summing correction on a cadmium telluride (CdTe)-based photon-counting detector in breast computed tomography (CT).

Approach: We employ a custom-built laboratory benchtop system using the X-THOR FX30 0.75-mm CdTe detector (Varex Imaging, Salt Lake City, Utah, United States) with a pixel pitch of 0.

View Article and Find Full Text PDF

Objective: To propose a dual-domain CBCT reconstruction framework (DualSFR-Net) based on generative projection interpolation to reduce artifacts in sparse-view cone beam computed tomography (CBCT) reconstruction.

Methods: The proposed method DualSFR-Net consists of a generative projection interpolation module, a domain transformation module, and an image restoration module. The generative projection interpolation module includes a sparse projection interpolation network (SPINet) based on a generative adversarial network and a full-view projection restoration network (FPRNet).

View Article and Find Full Text PDF

Conventional strategies aimed at mitigating beam-hardening artifacts in computed tomography (CT) can be categorized into two main approaches: (1) postprocessing following conventional reconstruction and (2) iterative reconstruction incorporating a beam-hardening model. While the former fails in low-dose and/or limited-data cases, the latter substantially increases computational cost. Although deep learning-based methods have been proposed for several cases of limited-data CT, few works in the literature have dealt with beam-hardening artifacts, and none have addressed the problems caused by randomly selected projections and a highly limited span.

View Article and Find Full Text PDF

Purpose: This study evaluates the performance of a kilovoltage x-ray image-guidance system equipped with a novel post-processing optimization algorithm on the newly introduced TAICHI linear accelerator (Linac).

Methods: A comparative study involving image quality tests and radiation dose measurements was conducted across six scanning protocols of the kV-cone beam computed tomography (CBCT) system on the TAICHI Linac. The performance assessment utilized the conventional Feldkamp-Davis-Kress (FDK) algorithm and a novel Non-Local Means denoising and adaptive scattering correction (NLM-ASC) algorithm.

View Article and Find Full Text PDF

Objective: We propose a dual-domain cone beam computed tomography (CBCT) reconstruction framework DualCBR-Net based on improved differentiable domain transform for cone-angle artifact correction.

Methods: The proposed CBCT dual-domain reconstruction framework DualCBR-Net consists of 3 individual modules: projection preprocessing, differentiable domain transform, and image post-processing. The projection preprocessing module first extends the original projection data in the row direction to ensure full coverage of the scanned object by X-ray.