This pilot study investigated the test-retest reliability of an RT3 accelerometer (RT3) for measuring motion in people with multiple sclerosis (MS). Ten people with MS (mean age 49 yr; Extended Disability Status Scale mean +/- standard deviation = 3.4 +/- 1.3) and ten nondisabled people (mean age 40 yr) wore the RT3 while they performed three discrete mobility tasks on two occasions separated by 1 week. The intraclass correlation coefficients (ICCs) calculated from the RT3 motion data for the group with MS were 0.64 for the 5-minute walk test (p = 0.01), 0.50 for the timed up and go test (p = 0.05), and 0.76 for the stair-climbing task (p = 0.002). For the control group, these values were 0.65 (p = 0.01), -0.04 (p = 0.54), and 0.39 (p = 0.11), respectively. We found that the RT3 can potentially provide stable data when measuring walking, but a more robust, yet participant-friendly, method of attaching the RT3 is required. Both participant groups demonstrated inconsistencies in motor-task performance, highlighting a potential source of measurement error that would need to be addressed when future studies are designed. Based on the results of the 5-minute walk test in this study, a sample of 53 participants would be required to obtain an ICC value with a 95% confidence interval of width 0.2 using two repeat measurements.

Download full-text PDF

Source
http://dx.doi.org/10.1682/jrrd.2005.09.0155DOI Listing

Publication Analysis

Top Keywords

reliability rt3
8
rt3 accelerometer
8
people multiple
8
multiple sclerosis
8
pilot study
8
people age
8
5-minute walk
8
walk test
8
rt3
6
accelerometer measuring
4

Similar Publications

Value of radiological depth of invasion in non-pT4 Oral tongue squamous cell carcinoma: implication for preoperative MR T-staging.

Eur Radiol

September 2024

State Key Laboratory of Oncology in South China, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangdong Provincial Clinical Research Center for Cancer, Sun Yat-Sen University Cancer Center, Guangzhou, 510060, China.

Objective: The prognostic stratification for oral tongue squamous cell carcinoma (OTSCC) is heavily based on postoperative pathological depth of invasion (pDOI). This study aims to propose a preoperative MR T-staging system based on tumor size for non-pT4 OTSCC.

Methods: Retrospectively, 280 patients with biopsy-confirmed, non-metastatic, pT1-3 OTSCC, treated between January 2010 and December 2017, were evaluated.

View Article and Find Full Text PDF

A number of xenobiotics interfere with thyroid hormone (TH) signaling. Although adequate supplies of TH are necessary for normal brain development, regulatory reliance on serum TH as proxies for brain TH insufficiency is fraught with significant uncertainties. A more direct causal linkage to neurodevelopmental toxicity induced by TH-system disrupting chemicals is to measure TH in the target organ of most concern, the brain.

View Article and Find Full Text PDF

Background: Orthognathic surgery is a reliable and safe method to improve maxillo-mandibular malformations. However, it is a complex procedure that can affect deeper structures and the terminal blood supply of specific areas, thereby affecting the results. Occasionally, despite careful digital planning and diagnosis, esthetic complications may occur, such as scarring or mucogingival alterations, including localized aseptic necrosis with associated recessions.

View Article and Find Full Text PDF

Introduction: Reliability in the use of placentome (including placenta, umbilical cord, and cord blood) biomarkers requires an understanding of their distributions. Here we aim to develop a simple and proper placenta sampling scheme, and to evaluate the placental distributions of biomarkers.

Methods: We developed a continuous cooling chain protocol off delivery room and cryo-subsampling method for placenta sampling.

View Article and Find Full Text PDF

A systematic review of the characteristics and validity of monitoring technologies to assess Parkinson's disease.

J Neuroeng Rehabil

March 2016

Instituto de Medicina Molecular, Faculdade de Medicina, Universidade de Lisboa, Avenida Professor Egas Moniz, 1649-028, Lisboa, Portugal.

Background: There is growing interest in having objective assessment of health-related outcomes using technology-based devices that provide unbiased measurements which can be used in clinical practice and scientific research. Many studies have investigated the clinical manifestations of Parkinson's disease using such devices. However, clinimetric properties and clinical validation vary among the different devices.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!