Computer-aided design (CAD) and computer-aided manufacturing systems have been adapted for specific use in prosthetics, providing practitioners with a means to digitally capture the shape of a patient's limb, modify the socket model using software, and automatically manufacture either a positive model to be used in the fabrication of a socket or the socket itself. The digital shape captured is a three-dimensional (3-D) model from which standard anthropometric measures can be easily obtained. This study recorded six common anthropometric dimensions from CAD shape files of three foam positive models of the residual limbs of persons with transtibial amputations. Two systems were used to obtain 3-D models of the residual limb, a noncontact optical system and a contact-based electromagnetic field system, and both experienced practitioners and prosthetics students conducted measurements. Measurements were consistent; the mean range (difference of maximum and minimum) across all measurements was 0.96 cm. Both systems provided similar results, and both groups used the systems consistently. Students were slightly more consistent than practitioners but not to a clinically significant degree. Results also compared favorably with traditional measurement, with differences versus hand measurements about 5 mm. These results suggest the routine use of digital shape capture for collection of patient volume information.

Download full-text PDF

Source
http://dx.doi.org/10.1682/jrrd.2006.08.0088DOI Listing

Publication Analysis

Top Keywords

persons transtibial
8
digital shape
8
models residual
8
systems
5
consistency precision
4
precision accuracy
4
accuracy optical
4
optical electromagnetic
4
electromagnetic shape-capturing
4
shape-capturing systems
4

Similar Publications

Meniscal root tears are recognized as an important pathology. Failure to recognize and to treat this pathology could lead to early-onset osteoarthritis, similar to a total meniscectomy. Surgical treatment is essential to restore meniscal function and to normalize compartment contact pressures, whenever there is joint overload and not severe cartilaginous damage.

View Article and Find Full Text PDF

The posterior cruciate ligament (PCL) is the strongest ligament of the knee and plays an important role in stabilizing the knee joint posteriorly. PCL tears are common injuries in sports injuries and traffic accidents; however, clinical outcomes after PCL reconstruction have not yet met clinicians' expectations, with a high postsurgery failure rate reported. Suture tape augmentation and supplementary fixation have shown ideal biomechanical properties in early studies.

View Article and Find Full Text PDF

Length of hospital stay and readmissions after major lower extremity amputation: a Danish nationwide registry study.

Acta Orthop

December 2024

Department of Orthopedic Surgery and Traumatology, Odense University Hospital, Odense, Denmark; Department of Clinical Research, University of Southern Denmark, Odense, Denmark.

Background And Purpose:  Major lower extremity amputation (MLEA) is associated with complications that may prolong length of hospital stay (LOS) and increase the risk of readmission. We primarily aimed to examine the LOS and risk of readmissions after MLEA in Denmark. Secondarily we investigated the time trends.

View Article and Find Full Text PDF

Objectives: Individuals with lower-limb amputations (LLA) often have deficits in balance and community walking ability. As a result, people with LLA are often sedentary. The aim of this study was to explore perceptions of physical activity from the perspective of people with LLA.

View Article and Find Full Text PDF

Background: While waiting to receive a prosthesis, individuals with amputations could benefit from using a temporary training prosthesis to expedite the rehabilitation process and prepare them for subsequent walking with their prosthesis.

Objectives: To design and build a temporary training prosthesis for people with a transtibial amputation.

Methodology: Various temporary training prostheses were designed and simulated using SolidWorks software, followed by fabricating and testing multiple prototypes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!