A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Corneal endothelial cell loss after cataract extraction by using ultrasound phacoemulsification versus a fluid-based system. | LitMetric

Purpose: To compare in vivo corneal endothelial cell loss (ECL) after fluid-based versus ultrasound phacoemulsification.

Methods: In this prospective randomized study, 2 groups of 21 patients underwent phacoemulsification with ultrasound (group 1) or a fluid-based system (group 2). A "divide and conquer" method with capsular bag lens implantation was performed. Cataracts graded up to nuclear opalescence 4.9 in Lens Opacities Classification System III (LOCS III) only were included. Endothelial cell density (ECD), percent hexagonality, endothelial cell area (ECA), coefficient of variation in cell size, and central corneal pachymetry were measured preoperatively, 7 days, 1 month, and 3 months after surgery. Statistical analysis was performed by using a 2-tailed Student t test.

Results: Average nuclear opalescence was identical in both groups (P = 0.908). Mean ECD was 1867 +/- 451 and 2031 +/- 400 cells/mm at 3 months postoperatively. Mean ECL was 498 +/- 415 (20.6% +/- 17.1%) and 302 +/- 302 cells/mm (13.3% +/- 13.2%) at 7 days, 589 +/- 342 (24.3% +/- 14%) and 254 +/- 214 cells/mm (11.2% +/- 9.1%) at 1 month, and 555 +/- 340 (22.9% +/- 14%) and 247 +/- 208 cells/mm (10.9% +/- 9.1%) at 3 months in groups 1 and 2, respectively. ECL was significantly lower for group 1 than for group 2 (P < 0.001) after the first postoperative month. A significant increase in ECA was also observed at the first and third (P = 0.012) postoperative months.

Conclusions: Our study showed significantly lower ECL after phacoemulsification for a fluid-based versus an ultrasound system. The fluid-based method was safer than conventional ultrasound in cataract surgery, with a nuclear opalescence graded up to 4.9 in the LOCS III classification.

Download full-text PDF

Source
http://dx.doi.org/10.1097/ICO.0b013e3181583115DOI Listing

Publication Analysis

Top Keywords

endothelial cell
16
+/-
14
nuclear opalescence
12
corneal endothelial
8
cell loss
8
fluid-based system
8
fluid-based versus
8
versus ultrasound
8
locs iii
8
+/- 14%
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!