Correlation processing for correction of phase distortions in subaperture imaging.

IEEE Trans Ultrason Ferroelectr Freq Control

Dept. of Electr. and Electron. Eng., Baskent Univ., Ankara.

Published: October 2012

Ultrasonic subaperture imaging combines synthetic aperture and phased array approaches and permits low-cost systems with improved image quality. In subaperture processing, a large array is synthesized using echo signals collected from a number of receive subapertures by multiple firings of a phased transmit subaperture. Tissue inhomogeneities and displacements in subaperture imaging may cause significant phase distortions on received echo signals. Correlation processing on reference echo signals can be used for correction of the phase distortions, for which the accuracy and robustness are critically limited by the signal correlation. In this study, we explore correlation processing techniques for adaptive subaperture imaging with phase correction for motion and tissue inhomogeneities. The proposed techniques use new subaperture data acquisition schemes to produce reference signal sets with improved signal correlation. The experimental test results were obtained using raw radio frequency (RF) data acquired from two different phantoms with 3.5 MHz, 128-element transducer array. The results show that phase distortions can effectively be compensated by the proposed techniques in real-time adaptive subaperture imaging.

Download full-text PDF

Source
http://dx.doi.org/10.1109/58.808871DOI Listing

Publication Analysis

Top Keywords

subaperture imaging
20
phase distortions
16
correlation processing
12
echo signals
12
correction phase
8
subaperture
8
tissue inhomogeneities
8
imaging phase
8
signal correlation
8
adaptive subaperture
8

Similar Publications

Light-field imaging is widely used in many fields, such as computer vision, graphics, and microscopy imaging, to record high-dimensional light information for abundant visual perception. However, light-field imaging systems generally have high system complexity and limited resolution. Over the last decades, lensless imaging systems have attracted tremendous attention to alleviate the restrictions of lens-based architectures.

View Article and Find Full Text PDF
Article Synopsis
  • The text outlines the development of a plug-and-play adaptive optics module for commercial microscopes that uses a deformable phase plate to improve image quality through aberration correction.
  • By estimating aberration profiles at multiple points and stitching corrected images together, the system aims to create high-quality full-field images.
  • An empirical method is introduced to optimize measurement time and correction quality by aligning the field segment size with the isoplanatic patch, enhancing overall performance in real-world applications.
View Article and Find Full Text PDF

Optical beams and starlight distorted by atmospheric turbulence can be corrected with adaptive optics systems to enable efficient coupling into single-mode fibers. Deformable mirrors, used to flatten the wavefront in astronomical telescopes, are costly, sensitive, and complex mechanical components that require careful calibration to enable high-quality imaging in astronomy, microscopy, and vision science. They are also impractical to deploy in large numbers for non-imaging applications like free-space optical communication.

View Article and Find Full Text PDF

The process of obtaining images of capillary vessels in the human eye's fundus using Doppler holography encounters difficulties due to ocular aberrations. To enhance the accuracy of these images, it is advantageous to apply an adaptive aberration correction technique. This study focuses on numerical Shack-Hartmann, which employs sub-pupil correlation as the wavefront sensing method.

View Article and Find Full Text PDF

Accurate measurement of a Radar Cross-Section (RCS) is a critical technical challenge in assessing the stealth performance and scattering characteristics of radar targets. Traditional RCS measurement methods are limited by high costs, sensitivity to environmental conditions, and difficulties in distinguishing local scattering features of targets. To address these challenges, this paper proposes a novel RCS measurement method based on enhanced imaging and scattering center extraction.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!