The Particle Concentrator-Brigham Young University Organic Sampling System (PC-BOSS) has been previously verified as being capable of measuring total fine particulate matter (PM2.5), including semi-volatile species. The present study was conducted to determine if the simple modification of a commercial speciation sampler with a charcoal denuder followed by a filter pack containing a quartz filter and a charcoal-impregnated glass (CIG) fiber filter would allow for the measurement of total PM2.5, including semi-volatile organic material. Data were collected using an R&P (Rupprecht and Pastasnik Co., Inc.) Partisol Model 2300 speciation sampler; an R&P Partisol speciation sampler modified with a BOSS denuder, followed by a filter pack with a quartz and a CIG filter; a Met One spiral aerosol speciation sampler (SASS); and the PC-BOSS from November 2001 to March 2002 at a U.S. Environmental Protection Agency (EPA) Science to Achieve Results (STAR) sampling site in Lindon, UT. Total PM2.5 mass, ammonium nitrate (both nonvolatile and semi-volatile), ammonium sulfate, organic carbon (both non-volatile and semi-volatile), and elemental carbon were determined on a 24-hr basis. Results obtained with the individual samplers were compared to determine the capability of the modified R&P speciation sampler for measuring total PM2.5, including semi-volatile components. Data obtained with the modified speciation sampler agreed with the PC-BOSS results. Data obtained with the two unmodified speciation samplers were low by an average of 26% because of the loss of semi-volatile organic material from the quartz filter during sample collection.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3155/1047-3289.58.1.65 | DOI Listing |
Anal Chim Acta
November 2024
Departament de Química, Física i Ciències Ambientals i del Sòl, Universitat de Lleida and AGROTECNIO-CERCA, Rovira Roure 191, 25198, Lleida, Spain.
Background: In a context of environmental monitoring around installations related to the nuclear fuel cycle, the Diffusive Gradient in Thin-films (DGT) technique captures the integrated concentration of U isotopes in their native environment, yielding comprehensive data on U origin (anthropogenic vs natural), total concentration, and mobility. However, for common deployment times (4-5 days) in moderately basic waters, none of the commercially available binding gels is adapted to measure the total U concentration. So, the development of novel DGT binding gels is timely.
View Article and Find Full Text PDFSci Total Environ
November 2024
Mote Limited, 40a George Street, Mount Eden, Auckland, New Zealand; School of Chemical Sciences, Faculty of Science, University of Auckland, Private Bag 92019, Auckland, New Zealand.
Worldwide, there is an increasing uptake of traffic management interventions aimed at reducing the impact of traffic related air pollution on public health. However, the evidence base linking the proposed changes with the resulting improvements in air quality is lacking. In this paper we present data from a micro-network of low-cost PM samplers collected from an isolated urban centre (Auckland, New Zealand).
View Article and Find Full Text PDFEnviron Res
November 2024
Institute of Environmental Assessment and Water Research (IDAEA-CSIC), 08034, Barcelona, Spain.
Although many studies have discussed the impact of Europe's air quality, very limited research focused on the detailed phenomenology of ambient trace elements (TEs) in PM in urban atmosphere. This study compiled long-term (2013-2022) measurements of speciation of ambient urban PM from 55 sites of 7 countries (Switzerland, Spain, France, Greece, Italy, Portugal, UK), aiming to elucidate the phenomenology of 20 TEs in PM in urban Europe. The monitoring sites comprised urban background (UB, n = 26), traffic (TR, n = 10), industrial (IN, n = 5), suburban background (SUB, n = 7), and rural background (RB, n = 7) types.
View Article and Find Full Text PDFEnviron Sci Pollut Res Int
May 2024
Savannah River Ecology Laboratory, University of Georgia, Aiken, SC, USA.
Mercury (Hg) is a prevalent and harmful contaminant that persists in the environment. For phytoremediation, it is important to discover which plants can bioaccumulate meaningful amounts of Hg while also tolerating its toxicity. Additionally, increasing biodiversity could create a more resilient and self-sustaining system for remediation.
View Article and Find Full Text PDFData Brief
April 2024
Lancaster Environment Centre, Lancaster University, Lancaster LA14YQ, UK.
The MONITOOL project (2017-2023) was carried out to describe the relationships between total dissolved and labile metal concentrations measured in spot water samples and in concurrently deployed Diffusive Gradients in Thin-films (DGTs) passive samplers, respectively. The ultimate aim was to adapt existing marine metal Environmental Quality Standards (EQS ) for DGTs, enabling their use in the context of the European Directives (the Water Framework Directive (WFD) and the Marine Strategy Framework Directive (MSFD)). Time-integrated metal concentrations provided by DGTs, representing several days, are an advantage compared to conventional spot sampling, especially in highly dynamic systems, such as transitional waters.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!