A simple and rapid method has been developed and validated for the quantitation of vincristine in human plasma by liquid chromatography/tandem mass spectrometry (LC/MS/MS) with atmospheric pressure chemical ionization using on-line solid-phase extraction. The method uses vinblastine as internal standard and the sample preparation is limited just to a plasma protein precipitation step. Further sample clean-up is carried out on-line through a perfusion column preceding an analytical phenyl LC column, the latter directly connected to the mass spectrometer. Quantitation is performed in multiple reaction monitoring mode using the transitions of m/z 825.3 --> 765.3 and 811.3 --> 751.3 for vincristine and vinblastine respectively. The assay was linear (r2 > or =0.99) in a concentration range from 0.1 to 500 ng/mL. Carry-over, measured on the experimental set-up, was less than 0.04%. Recovery for vincristine and the internal standard was within 90-95%. The intra-day and inter-day assay precision ranged from 1.2% to 6.8% RSD while mean percentage deviation from nominal value ranged from 0.01% to 6.1%. The proposed assay was found suitable for pharmacokinetics investigations and clinical therapeutic drug monitoring especially in pediatric cancer patients.

Download full-text PDF

Source
http://dx.doi.org/10.1002/rcm.3390DOI Listing

Publication Analysis

Top Keywords

vincristine human
8
human plasma
8
liquid chromatography/tandem
8
chromatography/tandem mass
8
mass spectrometry
8
internal standard
8
rapid sensitive
4
sensitive analysis
4
vincristine
4
analysis vincristine
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!