A group of 1,3-diarylurea derivatives, possessing a methylsulfonyl pharmacophore at the para-position of the N-1 phenyl ring, in conjunction with a N-3 substituted-phenyl ring (4-F, 4-Cl, 4-Me, 4-OMe), were designed and synthesized for evaluation as selective cyclooxygenase-2 (COX-2) inhibitors. In vitro COX-1/COX-2 isozyme inhibition structure-activity studies identified 1-(4-methylsulfonylphenyl)-3-(4-methoxyphenyl) urea (4e) as a potent COX-2 inhibitor (IC(50)=0.11 microM) with a high COX-2 selectivity index (SI=203.6) comparable to the reference drug celecoxib (COX-2 IC(50)=0.06 microM; COX-2 SI=405). The structure-activity data acquired indicate that the urea moiety constitutes a suitable scaffold to design new acyclic 1,3-diarylurea derivatives with selective COX-2 inhibitory activity.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.bmcl.2008.01.021 | DOI Listing |
Pharmazie
December 2024
Centre of Excellence for Pharmaceutical Sciences (Pharmacen™), North-West University, Potchefstroom, Republic of South Africa.
The COVID-19 pandemic caused global pandemonium, and due to an unprecedented global response, the popularity and use of (veterinary) ivermectin, amongst many other conceivable 'treatments', experienced a meteoric rise. Ivermectin is a macrocyclic lactone compound belonging to the avermectin drug class and is a registered medicine in many countries, although the most common use is as veterinary medicine. In this study, a fast HPLC method was developed and validated for the quantification of ivermectin in veterinary products that were used off-label by a substantial number of people during COVID-19.
View Article and Find Full Text PDFBrain Imaging Behav
January 2025
Macquarie Medical School, Macquarie University, Sydney, NSW, Australia.
Magnetic resonance imaging (MRI) is frequently used to monitor disease progression in multiple sclerosis (MS). This study aims to systematically evaluate the correlation between MRI measures and histopathological changes, including demyelination, axonal loss, and gliosis, in the central nervous system of MS patients. We systematically reviewed post-mortem histological studies evaluating myelin density, axonal loss, and gliosis using quantitative imaging in MS.
View Article and Find Full Text PDFJ Imaging Inform Med
January 2025
School of Computing, Informatics, and Decision Systems Engineering, Arizona State University, Tempe, AZ, USA.
Vision transformer (ViT)and convolutional neural networks (CNNs) each possess distinct strengths in medical imaging: ViT excels in capturing long-range dependencies through self-attention, while CNNs are adept at extracting local features via spatial convolution filters. While ViT may struggle with capturing detailed local spatial information, critical for tasks like anomaly detection in medical imaging, shallow CNNs often fail to effectively abstract global context. This study aims to explore and evaluate hybrid architectures that integrate ViT and CNN to leverage their complementary strengths for enhanced performance in medical vision tasks, such as segmentation, classification, reconstruction, and prediction.
View Article and Find Full Text PDFJ Imaging Inform Med
January 2025
Department of Radiology, University of Pennsylvania Perelman School of Medicine, 3400 Spruce St., Philadelphia, PA, 19104, USA.
Integration of artificial intelligence (AI) into radiology practice can create opportunities to improve diagnostic accuracy, workflow efficiency, and patient outcomes. Integration demands the ability to seamlessly incorporate AI-derived measurements into radiology reports. Common data elements (CDEs) define standardized, interoperable units of information.
View Article and Find Full Text PDFCardiovasc Eng Technol
January 2025
Institute for Medical Engineering and Science, Massachusetts Institute of Technology, MA, Cambridge, USA.
Purpose: Atrial fibrillation (AF) is the most common chronic cardiac arrhythmia that increases the risk of stroke, primarily due to thrombus formation in the left atrial appendage (LAA). Left atrial appendage occlusion (LAAO) devices offer an alternative to oral anticoagulation for stroke prevention. However, the complex and variable anatomy of the LAA presents significant challenges to device design and deployment.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!