The utility of multiple imaging modalities to diagnose acute aortic dissection.

CJEM

Department of Emergency Medicine, Dalhousie University, Halifax, Nova Scotia, Canada.

Published: January 2008

A 21-year-old man with Marfan syndrome and known aortic root aneurysm presented to our emergency department with symptoms suggestive of acute aortic dissection. The patient was hemodynamically stable and bilateral upper extremity blood pressures were similar. There was no mediastinal widening on portable chest radiograph. Both contrast CT and retrograde angiography of the aorta failed to identify dissection. Subsequent transesophageal echocardiography demonstrated a Stanford classification type A dissection. This case demonstrates the utility of multiple imaging modalities for identifying aortic dissection in high-risk patients.

Download full-text PDF

Source
http://dx.doi.org/10.1017/s1481803500010046DOI Listing

Publication Analysis

Top Keywords

aortic dissection
12
utility multiple
8
multiple imaging
8
imaging modalities
8
acute aortic
8
dissection
5
modalities diagnose
4
diagnose acute
4
aortic
4
dissection 21-year-old
4

Similar Publications

Prognostic Value of D-Dimer in Acute Type A Aortic Dissection and Intramural Hematoma: Observations from the Acute Aortic Syndrome Group of the Registry of Acute Non-Traumatic Chest Pain in China.

J Am Heart Assoc

January 2025

Department of Cardiovascular Surgery, Beijing Anzhen Hospital, Capital Medical University, and The Key Laboratory of Cardiovascular Remodeling-related Diseases, Ministry of Education, and Beijing Institute of Heart Lung and Blood Vessel Disease Beijing China.

Background: Acute type A aortic dissection (AAD) and acute type A intramural hematoma (AIMH) are life-threatening conditions with high mortality rates, and prognostic indicators are critical for guiding urgent treatment decisions. We assessed the prognostic significance of admission D-dimer levels in patients with AAD and AIMH.

Methods And Results: The prospective, multicenter, observational study in China recruited participants from 2013 to 2019.

View Article and Find Full Text PDF

Background And Objective: Patients with thoracic aortic aneurysm and dissection (TAAD) are often asymptomatic but present acutely with life threatening complications that necessitate emergency intervention. Aortic diameter measurement using computed tomography (CT) is considered the gold standard for diagnosis, surgical planning, and monitoring. However, manual measurement can create challenges in clinical workflows due to its time-consuming, labour-intensive nature and susceptibility to human error.

View Article and Find Full Text PDF

Development and Validation of a Diagnostic Model for Stanford Type B Aortic Dissection Based on Proteomic Profiling.

J Inflamm Res

January 2025

Department of Vascular Surgery, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, People's Republic of China.

Purpose: Stanford Type B Aortic Dissection (TBAD), a critical aortic disease, has exhibited stable mortality rates over the past decade. However, diagnostic approaches for TBAD during routine health check-ups are currently lacking. This study focused on developing a model to improve the diagnosis in a population.

View Article and Find Full Text PDF

Type B aortic dissection (TBAD) represents a serious medical emergency with up to a 50% associated 5-year mortality caused by thoracic aorta, dissection-associated aneurysmal (DAA) degeneration, and rupture. Unfortunately, conventional size-related diagnostic methods cannot distinguish high-risk DAAs that benefit from surgical intervention from stable DAAs. Our goal is to use DAA stiffness measured with magnetic resonance elastography (MRE) as a biomarker to distinguish high-risk DAAs from stable DAAs.

View Article and Find Full Text PDF

We report a case of mesenteric ischemia after thoracic endovascular aortic repair (TEVAR) for chronic type B aortic dissection performed at a different institution. Computed tomography angiography findings indicated that the previous TEVAR had been deployed distally into the false lumen. To mitigate this, a large fenestration was created between the false lumen and true lumen.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!