A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A new evaluation method for +Gz tolerance with loratadine by using a near-infrared spectroscopy. | LitMetric

A new evaluation method for +Gz tolerance with loratadine by using a near-infrared spectroscopy.

Dyn Med

Aeromedical Laboratory, Japan Air Self-Defense Force, Tachikawa, Tokyo, Japan.

Published: January 2008

Background: Loratadine (Claritin), an over-the-counter antihistamine in U.S. and UK, is acceptable for use without adverse side effects by aircrew with mild or moderate allergic or other situations requiring an antihistamine. Although +Gz (head to foot direction) tolerance testing for aircrew with loratadine has not been documented in the published literature, it is commonly accepted that loratadine dose not effect +Gz tolerance. The purpose of this study was to offer and validate a new evaluation method for +Gz tolerance testing with loratadine by using a near-infrared spectroscopy (NIRS).

Methods: A double-blind, placebo-controlled, randomized, crossover protocol was used to administer 10 mg of loratadine or placebo in nine healthy subjects. The subjects didn't wear anti-G suit. The +Gz exposure profiles consisted of, in series, a gradual onset ran (0.1 G.sec-1) to the subject's visual end-point (peripheral light loss) or loss of consciousness (GLOC), and rapid onset run (1.0 G.sec-1) to the subject's same end-point. In this study, G-level tolerance was defined as the +Gz level at visual end-point and/or at GLOC. As a subject's G-duration tolerance, we measured the total time (seconds) during rapid onset run. Otherwise, to confirm the effect of loratadine on +Gz tolerance, we measured the cerebral NIRS variables (hemoglobin concentration changes and tissue oxygenation index) as a new quantitative method for +Gz tolerance during a centrifuge experiments.

Results: No significant differences were observed in +Gz tolerance (+Gz level, duration time and NIRS variables) between subjects taking loratadine and placebo.

Conclusion: Our results demonstrate that loratadine has no detectable effect on +Gz tolerance by using a new method with cerebral NIRS variables and the traditional method with +Gz level and duration time. This study represents the first use of a quantitative parameter such as cerebral NIRS variables to assess the effects of a drug on acceleration tolerance.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2265702PMC
http://dx.doi.org/10.1186/1476-5918-7-3DOI Listing

Publication Analysis

Top Keywords

+gz tolerance
28
method +gz
16
nirs variables
16
+gz
12
+gz level
12
cerebral nirs
12
tolerance
11
loratadine
9
evaluation method
8
loratadine near-infrared
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!