Purpose: Proteomic profiling using surface enhanced laser desorption/ionization time of flight mass spectrometry (SELDI-TOF MS) enables the identification of biomarkers for cancer. We evaluated the sensitivity and specificity of SELDI-TOF MS for detection of established hepatocellular cancer (HCC) and compared it against alpha-fetoprotein (AFP), Lens culinaris agglutinin-reactive AFP (AFP-L3), and prothrombin induced by vitamin K absence-II (PIVKA-II).

Experimental Design: Forty-one patients with HCC and 51 patients with hepatitis C cirrhosis were enrolled. Serum was analyzed by SELDI-TOF MS using three Ciphergen protein array types.

Results: An 11-peak algorithm for HCC detection was identified. Using the AFP cutoff of 20 ng/mL, the sensitivity was 73% and the specificity was 71%. Using the AFP-L3 cutoff of 10% yielded a sensitivity of 63% and a specificity of 94%. Using the PIVKA-II cutoff of 125 milliabsorbance units (mAU), the sensitivity was 84% and the specificity was 69%. Overall, the sensitivity and specificity of SELDI-TOF MS for HCC were 79% and 86%, respectively. In multivariate analysis, the 11-peak SELDI profile was predictive of HCC independent of AFP, PIVKA, and AFP-L3. Among eight patients with the largest tumor size of <2 cm, SELDI-TOF MS correctly identified seven whereas AFP, AFP-L3, and PIVKA-II identified only three, one, and one, respectively. One of the 11 peaks in the SELDI-TOF MS 11-peak predictor from SELDI-TOF MS was identified as cystatin C.

Conclusions: SELDI-TOF MS accurately distinguished patients with HCC from those with hepatitis C virus cirrhosis, was more accurate than traditional biomarkers in identifying small tumors, and should be further evaluated.

Download full-text PDF

Source
http://dx.doi.org/10.1158/1078-0432.CCR-07-0586DOI Listing

Publication Analysis

Top Keywords

sensitivity specificity
8
specificity seldi-tof
8
sensitivity
5
specificity
5
hcc
5
serum proteomics
4
proteomics biomarkers
4
biomarkers hepatocellular
4
hepatocellular carcinoma
4
carcinoma chronic
4

Similar Publications

Background And Purpose: Synthetic MRI utilizes the quantitative relaxometry parameters to generate multiple contrast images through a single acquisition. We tried to explore the utility of synthetic MRI derived relaxometry parameters in evaluation of ring enhancing lesions of brain.

Materials And Methods: This was a prospective study.

View Article and Find Full Text PDF

Purpose: To evaluate stone free rate (SFR) predictivity of three different scoring systems in patients with kidney stones larger than 20 millimeters undergoing retrograde intrarenal surgery(RİRS).

Methods: Digital records of a total of 166 patients were reviewed retrospectively. Epidemiological characteristics (age, gender, medical history) of the patients, stone and affected kidney characteristics (size, volume, location, density, opaque, presence of urinary system anomaly, presence of stones in different calyx, number of stones, lower pole stone, renal infundibulopelvic angle (IPA), renal infundibulopelvic length (RIL), hydronephrosis), and operative characteristics (preoperative ureteral stent, operation duration, postoperative residual fragments, hospitalization time and complications were recorded.

View Article and Find Full Text PDF

The accurate diagnosis of aging-related neurocognitive disorders as early as possible, even in a phase that is characterized by the absence of clinical symptoms, is nowadays the holy grail of the neurosciences. R4Alz-R is a novel cognitive tool designed to objectively detect the subtle cognitive changes that emerge as the very first result of the aging processes and could be developed and broadened in a continuum from healthy aging to subjective cognitive impairment (SCI) and mild cognitive impairment (MCI), before reaching some type of dementia. The goal of the present study was to examine whether the R4Alz-R battery has the potential to detect these subtle changes.

View Article and Find Full Text PDF

Carbon-based light addressable potential aptasensor based on the synergy of C-MXene@rGO and OPD@NGQDs for low-density lipoprotein detection.

Mikrochim Acta

December 2024

School of Life and Environmental Sciences, School of Intellectual Property, Guilin University of Electronic Technology, Guilin, Guangxi, 541004, People's Republic of China.

A novel carbon-based light-addressable potentiometric aptasensor (C-LAPS) was constructed for detection low-density lipoprotein (LDL) in serum. Carboxylated TiC MXene @reduced graphene oxide (C-MXene@rGO) was used as interface and o-phenylenediamine functionalized nitrogen-doped graphene quantum dots (OPD@NGQDs) as the photoelectric conversion element. The photosensitive layers composed of OPD@NGQDs/C-MXene@rGO exhibit superior photoelectric conversion efficiency and excellent biocompatibility, which contribute to an improved response signal.

View Article and Find Full Text PDF

Novel isothermal nucleic acid amplification method for detecting malaria parasites.

Appl Microbiol Biotechnol

December 2024

Laboratório de Pesquisa em Malária, Instituto Oswaldo Cruz (IOC), Fundação Oswaldo Cruz (Fiocruz), Rio de Janeiro, Brazil.

Malaria, a parasitic disease caused by Plasmodium spp. and transmitted by Anopheles mosquitoes, remains a major global health issue, with an estimated 249 million cases and 608,000 deaths in 2022. Rapid and accurate diagnosis and treatment are crucial for malaria control and elimination.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!