A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Carbon dioxide field flooding reduces neurologic impairment after open heart surgery. | LitMetric

Background: Air emboli released from incompletely deaired cardiac chambers may cause neurocognitive decline after open heart surgery. Carbon dioxide (CO2) field flooding is reported to reduce residual intracavital air during cardiac surgery. A protective effect of carbon dioxide insufflation on postoperative brain function remains unproven in clinical trials.

Methods: Eighty patients undergoing heart valve operations by median sternotomy were randomly assigned to either CO2 insufflation (group I, n = 39) or unprotected controls (group II, n = 41). Preoperative evaluation included neurocognitive test batteries consisting of six different tests, and objective measurements of brain function by means of P300 wave auditory-evoked potentials (peak latencies, ms). Neurocognitive testing and P300 measurements were repeated on postoperative day 5. Neurocognitive deficit (ND) was defined as a 20% decrement in two or more tests.

Results: Preoperatively, P300 peak latencies did not differ between groups (374 +/- 75 vs 366 +/- 72 ms, not significant [n.s.]). Five days after surgery, P300 peak latencies were significantly shorter with CO2 protection as compared with the unprotected control group (group I: 390 +/- 68 ms, group II: 429 +/- 75 ms, p = 0.02). Clinical outcome was comparable as for mortality (group I: 1 patient; group II: 2 patients) and cerebrovascular events or confusional syndromes (group I: 5 patients; group II: 4 patients) or other clinical variables as intubation time or hospital stay. Neurocognitive test batteries did not reveal differences between groups.

Conclusions: Shorter P300 peak latencies after surgery indicate less brain damage in patients who underwent heart valve operations with CO2 flooding of the thoracic cavity. Even if these findings were not supported by clinical results or neurocognitive test batteries in our cohort, carbon dioxide field flooding has proven efficiency and should be advocated for all patients undergoing open heart surgery.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.athoracsur.2007.08.047DOI Listing

Publication Analysis

Top Keywords

carbon dioxide
16
peak latencies
16
field flooding
12
open heart
12
heart surgery
12
neurocognitive test
12
test batteries
12
p300 peak
12
group patients
12
group
9

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!