Background: Augmentation Index (AIx) is related to cardiovascular diseases, risk, and mortality. AIx is associated with heart rate but the effect of aortic stiffness on this relationship has not been studied. The purpose of our study was to investigate the relationship between AIx and heart rate at different aortic stiffness levels.

Methods: The study consisted of 425 normotensive and untreated hypertensive subjects. Wave reflections and pulse-wave velocity (PWV) were determined by the Sphygmocor and the Complior systems, respectively.

Results: AIx was independently associated with heart rate, age, gender, height, mean blood pressure (BP) and the effective reflection site distance (ERD). The population was divided into three groups of those with different PWV levels (tertiles). The regression lines for AIx with heart rate differed significantly between the 3rd and the other two tertiles of PWV (P = 0.039 for slopes and P = 0.002 for intercepts). This difference remained significant even after adjustment for age, gender, height, mean BP, and distance of wave reflections.

Conclusions: A significantly stronger correlation of AIx with heart rate was observed in subjects with higher levels of aortic stiffness as compared to those with lower levels; namely, the same increase in the heart rate between subjects, induced a greater decrease in the AIx at higher compared to lower PWV levels. The correction of AIx for heart rate should be reconsidered based on the aortic stiffness level. This finding has implications for interventional studies that aim to improve central hemodynamics but simultaneously affect heart rate. Further studies that show acute modifications of heart rate at different arterial stiffness levels are required to support these findings.

Download full-text PDF

Source
http://dx.doi.org/10.1038/ajh.2007.52DOI Listing

Publication Analysis

Top Keywords

heart rate
40
aortic stiffness
20
aix heart
16
heart
10
rate
9
wave reflections
8
aix
8
associated heart
8
rate aortic
8
age gender
8

Similar Publications

Cardiac acetylcholinesterase and butyrylcholinesterase have distinct localization and function.

Am J Physiol Heart Circ Physiol

January 2025

Comenius University Bratislava, Faculty of Pharmacy, Department of Pharmacology and Toxicology, Bratislava, Slovakia.

Cholinesterase (ChE) inhibitors are under consideration to be used in the treatment of cardiovascular pathologies. A prerequisite to advancing ChE inhibitors into the clinic is their thorough characterization in the heart. The aim here was to provide a detailed analysis of cardiac ChE to understand their molecular composition, localization, and physiological functions.

View Article and Find Full Text PDF

The duration of mechanical systole-also termed the flow time (FT) or left ventricular ejection time (LVET)-is measured by Doppler ultrasound and increasingly used as a stroke volume (SV) surrogate to guide patient care. Nevertheless, confusion exists as to the determinants of FT and a critical evaluation of this measure is needed. Using Doppler ultrasound of the left ventricular outflow tract velocity time integral (LVOT VTI) as well as strain and strain rate echocardiography as grounding principles, this brief commentary offers a model for the independent influences of FT.

View Article and Find Full Text PDF

Introduction: Obstructive sleep apnoea (OSA) in children is associated with numerous adverse outcomes, including elevated blood pressure. While the associations between OSA, obesity, and autonomic dysfunction are recognised, the precise mechanisms linking these factors and their relationship with elevated blood pressure in children remain unclear.

Methods: This retrospective case series included 76 children with OSA.

View Article and Find Full Text PDF

Background: GLP-1 RAs improve cardiometabolic outcomes in obese, diabetic, and heart failure patients. Data on the safety and efficacy of GLP-1 RA in advanced heart failure with durable LVAD is limited.

Objectives: To assess the safety and efficacy of GLP-1 RA in durable LVAD patients.

View Article and Find Full Text PDF

Pimobendan oral solution is bioequivalent to pimobendan chewable tablets in beagle dogs.

J Vet Intern Med

January 2025

Boehringer Ingelheim Pharma GmbH & Co., Ingelheim, Germany.

Background: Myxomatous mitral valve disease (MMVD) is frequently diagnosed in small breed dogs. Pimobendan oral solution has been developed to improve dosing accuracy in small and toy breed dogs.

Hypothesis/objectives: Demonstrate bioequivalence of pimobendan oral solution with pimobendan chewable tablets using a pharmacokinetic and a pharmacodynamic study in healthy purpose bred dogs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!