Cardiac and respiratory motion can cause artifacts in computed tomography scans of the chest. The authors describe a new method for reducing these artifacts called pixel-specific back-projection (PSBP). PSBP reduces artifacts caused by in-plane motion by reconstructing each pixel in a frame of reference that moves with the in-plane motion in the volume being scanned. The motion of the frame of reference is specified by constructing maps that describe the motion of each pixel in the image at the time each projection was measured; these maps are based on measurements of the in-plane motion. PSBP has been tested in computer simulations and with volunteer data. In computer simulations, PSBP removed the structured artifacts caused by motion. In scans of two volunteers, PSBP reduced doubling and streaking in chest scans to a level that made the images clinically useful. PSBP corrections of liver scans were less satisfactory because the motion of the liver is predominantly superior-inferior (S-I). PSBP uses a unique set of motion parameters to describe the motion at each point in the chest as opposed to requiring that the motion be described by a single set of parameters. Therefore, PSBP may be more useful in correcting clinical scans than are other correction techniques previously described.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/42.500142 | DOI Listing |
Ergonomics
January 2025
School of Kinesiology and Health Studies, Queen's University, Kingston, Ontario, Canada.
Age is associated with increased tissue stiffness and a higher risk of low back pain, particularly in older, sedentary workers who spend long periods sitting. This study explored how trunk stiffness changes with age and its relationship with posture during prolonged sitting in a sample of 37 women aged 20-65 years. Age was assessed as both Chronological Age and Fitness Age, with trunk stiffness measured using a passive trunk flexion apparatus.
View Article and Find Full Text PDFJ Nanobiotechnology
January 2025
School of Medical Imaging, Xuzhou Medical University, Xuzhou, 221004, China.
With the progress of atherosclerosis (AS), the arterial lumen stenosis and compact plaque structure, the thickening intima and the narrow gaps between endothelial cells significantly limit the penetration efficiency of nanoprobe to plaque, weakening the imaging sensitivity and therapy efficiency. Thus, in this study, a HO-NIR dual-mode nanomotor, Gd-doped mesoporous carbon nanoparticles/Pt with rapamycin (RAPA) loading and AntiCD36 modification (Gd-MCNs/Pt-RAPA-AC) was constructed. The asymmetric deposition of Pt on Gd-MCNs catalyzed HO at the inflammatory site to produce O, which could promote the self-motion of the nanomotor and ease inflammation microenvironment of AS plaque.
View Article and Find Full Text PDFAtten Percept Psychophys
January 2025
Department of Developmental and Social Psychology, University of Padova, via Venezia 8, 35131, Padova, Italy.
Numerical and nonnumerical magnitudes can be represented along a hypothetical left-to-right continuum, where smaller quantities are associated with the left side and larger quantities with the right side. However, these representations are flexible, as their intensity and direction can be modulated by various contextual cues and task demands. In four experiments, we investigated the spatial representation of visual speed.
View Article and Find Full Text PDFInsights Imaging
January 2025
IRCCS Istituto Ortopedico Galeazzi, Milan, Italy.
Entrapment neuropathies at the elbow are common in clinical practice and require an accurate diagnosis for effective management. Understanding the imaging characteristics of these conditions is essential for confirming diagnoses and identifying underlying causes. Ultrasound serves as the primary imaging modality for evaluating nerve structure and movement, while MRI is superior for detecting muscle denervation.
View Article and Find Full Text PDFEur Radiol
January 2025
Departments of Radiology and Nuclear Medicine, Erasmus MC - Sophia Children's Hospital, Rotterdam, the Netherlands.
Chest imaging in children presents unique challenges due to varying requirements across age groups. For chest radiographs, achieving optimal images often involves careful positioning and immobilisation techniques. Antero-posterior projections are easier to obtain in younger children, while lateral decubitus radiographs are sometimes used when expiratory images are difficult to obtain and for free air exclusion.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!