A new method for distortion correction of electronic endoscope images.

IEEE Trans Med Imaging

Dept. of Inf. & Comput. Sci., Chiba Univ.

Published: October 2012

A new method to correct the barrel distortion of an electronic endoscope image is presented. A correction model assuming circularly symmetric distortion is introduced with the following model parameters: the center of distortion and the coefficients of polynomials representing the distortion correction in the radial direction. If the imaging system is distortion-free, straight lines in the object space should be imaged as straight lines. Based on this criterion, a distorted image of a standard pattern consisting of a grid of several straight lines is recorded, and the model parameters are then estimated as a basis for straightening distorted lines. This method has the advantage of not needing a careful placement of the standard pattern for calibration. Correction results are presented for the grid pattern chart to verify a sufficient degree of correction. Examples of distortion correction of real intestinal images and physicians' comments are also presented.

Download full-text PDF

Source
http://dx.doi.org/10.1109/42.414620DOI Listing

Publication Analysis

Top Keywords

distortion correction
12
straight lines
12
electronic endoscope
8
model parameters
8
standard pattern
8
correction
6
distortion
5
method distortion
4
correction electronic
4
endoscope images
4

Similar Publications

We theoretically demonstrate that ponderomotive interactions near the electron cross-over can be used for aberration correction in ultrafast electron microscopes. Highly magnified electron shadow images from SiN thin films are utilized to visualize the distortions induced by spherical aberrations. Our simulations of electron-light interactions indicate that spherical aberrations can be compensated resulting in an aberration-free angle of 8.

View Article and Find Full Text PDF

Stitching interferometry is essential for X-ray mirror metrology where lateral distortion and pixel size are critical factors influencing its accuracy. Simulations and experiments reveal that 1% error in pixel size causes a 2% deviation in the radius of curvature. After correcting pixel size, the stitching profile error of an elliptical mirror reduces from 2 μm to 250 nm (peak-to-valley).

View Article and Find Full Text PDF

Correcting scale distortion in RNA sequencing data.

BMC Bioinformatics

January 2025

Department of Radiology, University of Minnesota, Minneapolis, MN, 55455, USA.

RNA sequencing (RNA-seq) is the conventional genome-scale approach used to capture the expression levels of all detectable genes in a biological sample. This is now regularly used for population-based studies designed to identify genetic determinants of various diseases. Naturally, the accuracy of these tests should be verified and improved if possible.

View Article and Find Full Text PDF

Patch-based dual-domain photon-counting CT data correction with residual-based WGAN-ViT.

Phys Med Biol

January 2025

Electrical and Computer Engineering, University of Massachusetts Lowell, Ball Hall, 1 University Ave, Lowell, Massachusetts, 01854, UNITED STATES.

Objective: X-ray photon-counting detectors (PCDs) have recently gained popularity due to their capabilities in energy discrimination power, noise suppression, and resolution refinement. The latest extremity photon-counting computed tomography (PCCT) scanner leverages these advantages for tissue characterization, material decomposition, beam hardening correction, and metal artifact reduction. However, technical challenges such as charge splitting and pulse pileup can distort the energy spectrum and compromise image quality.

View Article and Find Full Text PDF

Structural maintenance of chromosomes (SMC) are ubiquitously distributed proteins involved in chromosome organization. Deletion of causes severe growth phenotypes in many organisms. Surprisingly, can be deleted in , a member of the phylum, without any apparent growth phenotype.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!